Evidence map›Paper›PMID 40619362›Full record

ArticleBMC medical imaging2025

Effects of trauma mattress on dose and image quality of paediatric whole-body computed tomography examinations.

Jacob Leonard Ago, Stephen Inkoom, Benard Ohene-Botwe, Alise Larsen, Ingerd Skaaret Berg

Abstract read
In one paragraph

Article in BMC medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jacob Leonard AgoDepartment of Radiography, School of Biomedical and Allied Health Sciences, College of Health Sciences, University of Ghana, Korle-Bu Campus, Korle-Bu, P. O. Box KB 143, Accra, Ghana. jacobleonardago@gmail.com.
Stephen InkoomDepartment of Nuclear Safety and Security, School of Nuclear and Allied Sciences, College of Basic and Applied Sciences, University of Ghana, Atomic Campus, Accra, Ghana.
Benard Ohene-BotweDepartment of Midwifery and Radiography, School of Health & Medical Sciences, City, University of London, London, UK.
Alise LarsenMedical Physics Unit, Innlandet Hospital, Hamar, Norway.
Ingerd Skaaret BergMedical Physics Unit, Innlandet Hospital, Hamar, Norway.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhole-body computed tomography (WBCT) is the preferred first line investigation for patients with suspected multiple traumas. To decrease the potential for increased spinal injury, bearing devices, including trauma mattress, are recommended for adequate spine immobilisation. This study assesses the effect of trauma mattress on the dose and image quality of WBCT examinations.

methodsThis was a phantom-based experimental study. Two different paediatric whole-body anthropomorphic phantoms from Kyoto Kagaku were used: newborn (PBU-80) and 5-year-old (PBU-70). Optimised WBCT protocols were scanned with and without a trauma mattress. The effective dose (ED) from each protocol was estimated from CT-Expo software and from the product of the dose length product and dose conversion coefficient (DLP-E(k)) methods, while image quality was assessed subjectively and objectively.

resultsThe use of trauma mattress increased the mean ED and decreased the SNR of the 5-year-old phantom examinations by 7.0% (p = 0.776) and 21.4% (p = 0.194) respectively. In contrast, there was a 43.9% increase in ED (p = 0.019) and a 16.5% decrease in SNR (p = 0.221) when trauma mattress was used for the newborn phantom examinations. The differences in the mean ED from CT-Expo and the DLP-E (k) were not statistically significant (p = 0.258 and 0.278 for newborn and 5-year-old phantoms, respectively). The median organ doses estimated from all examinations performed without a trauma mattress were significantly lower than examinations performed with a trauma mattress (p = 0.001). The use of the trauma mattress increased the average tube voltage, tube current, volume computed tomography dose index (CTDI

conclusionThe use of trauma mattress increased the ED and decreased the SNR during the WBCT examinations, albeit at different levels for the newborn and 5-year-old phantoms. Consequently, medical imaging professionals should restrict the use of bearing devices to examinations that justifiably require them. Appropriate adjustments in scan protocols for different body habitus and the use of alternative immobilisation techniques, where necessary, will further enhance patient safety during paediatric WBCT examinations.

Indexed as

BedsRadiation DosageTomography, X-Ray ComputedWhole Body ImagingChildChild, PreschoolHumansInfantInfant, NewbornPhantoms, ImagingAnthropomorphic PhantomBearing devicesDose optimisationImmobilising devicesTrauma mattressWhole-body computed tomography

Identifiers

PMID40619362
PMCPMC12232779

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.