Evidence map›Paper›PMID 40617616›Full record

Observational studyBMJ open2025

Evaluation of optical sensor technology for the early detection of peripheral intravenous infiltration in neonates: a retrospective cohort study.

Matheus F P T van Rens, Kevin Hugill, Robin van der Lee, Airene L V Francia, Fredericus H J van van Loon, Mohammad A A Bayoumi

Abstract readObservational Study
In one paragraph

Observational study in BMJ open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Matheus F P T van RensNeonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar.ORCID http://orcid.org/0000-0001-9359-0895
Kevin HugillNursing Education, Hamad Medical Corporation, Doha, Qatar.
Robin van der LeeDepartment of Neonatology, Amalia Children's Hospital, Nijmegen, Gelderland, The Netherlands.
Airene L V FranciaNeonatal Intensive Care Unit, Hamad Medical Corporation, Doha, Qatar.
Fredericus H J van van LoonDepartment of Anaesthesiology, Catharina Hospital, Eindhoven, The Netherlands.ORCID http://orcid.org/0000-0003-3854-6976
Mohammad A A BayoumiHamad Medical Corporation, Doha, Qatar moh.abdelwahab@hotmail.com.ORCID http://orcid.org/0000-0002-2627-4806

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to evaluate the utility of optical sensor-based technology in mitigating the frequency and severity of peripheral intravenous infiltration and/or extravasation (PIVIE) in neonates.

designSingle-centre, retrospective, observational cohort study.

settingTertiary-level neonatal intensive care unit (NICU) (112 cots) at the Women's Wellness and Research Centre (WWRC), Hamad Medical Corporation (HMC), Doha, Qatar, January 2019-December 2022.

participantsAll neonates admitted to the NICU requiring intravenous therapy via a neonatal short peripheral intravenous catheter (n-SPC) were included. Participants were excluded if the insertion was unsuccessful, if they had incomplete data, or if they received intravenous therapy exclusively through alternative vascular access devices.

interventionsThe study analysed two cohorts representing different clinical practices over two distinct periods. In the conventional cohort (Phase 1, 2019-2020), PIVIE detection relied solely on periodic 'Touch Look Compare (TLC)' assessments. In the ivWatch cohort (Phase 2, 2021-2022), continuous optical sensor-based monitoring using the ivWatch system was implemented alongside TLC assessments. This sequential design allowed for a comparison of outcomes between the two phases. OUTCOME MEASUREMENTS: The primary outcomes were the occurrence and severity of PIVIE. Secondary outcomes included the influence of patient demographics, vascular access characteristics, and management details on PIVIE incidence and severity.

resultsOver the 4-year data collection period, 32 713 peripheral intravenous catheters were analysed across two cohorts. PIVIE was the most common reason for unplanned device removal. In the conventional cohort (Phase 1, 2019-2020), 4941 infiltration events were reported (29.9%), compared with 4872 events (30.1%) in the ivWatch cohort (Phase 2, 2021-2022). However, severity measures using the Intravenous Extravasation Grading Scale (IEGS) revealed a marked reduction in severe PIVIE cases, with severe events decreasing from 243 (4.9%) in the conventional cohort to 54 (1.1%) in the ivWatch cohort (p<0.001).

conclusionsPIVIE remains a frequent complication in neonatal vascular access. Continuous site monitoring with optical sensor technology was associated with earlier detection of PIVIE events and reduced IEGS severity scores. These findings highlight the potential of integrating sensor-based monitoring with traditional observational methods to improve patient outcomes in neonatal care.

Indexed as

Catheterization, PeripheralExtravasation of Diagnostic and Therapeutic MaterialsEarly DiagnosisFemaleHumansInfant, NewbornIntensive Care Units, NeonatalMaleQatarRetrospective StudiesDigital TechnologyInformation technologyNeonatal intensive & critical careNEONATOLOGYNursing CareQUALITATIVE RESEARCH

Identifiers

PMID40617616
PMCPMC12228456

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.