Evidence map›Paper›PMID 40616088›Full record

ArticleBMC musculoskeletal disorders2025

Modified PHILOS system utilizing a single bone cement calcar screw achieves optimal fixation stability and promotes bone healing: a biomechanical study and corresponding case series.

Chenyi Huang, Bing Liu, Zongchao Liu, Wenqiang Xu, Zhenming Hu

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [Research progress on medial support augmentation techniques for proximal humeral fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chenyi Huang *Department of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, P.R. China.
Bing Liu *Department of Orthopedics, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, No. 182, Chunhui Road, Luzhou, Sichuan Province, 646000, P.R. China.
Zongchao LiuDepartment of Orthopedics, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, No. 182, Chunhui Road, Luzhou, Sichuan Province, 646000, P.R. China.
Wenqiang XuDepartment of Orthopedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210028, Jiangsu Province, P.R. China. xuwenqiangtrauma@163.com.
Zhenming HuDepartment of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, P.R. China. spinecenter_hu@163.com.

Funding

the Hejiang County People's Hospital - Southwest Medical University Cooperative Project (2021) 2022HJXNYD09
6 · The paper itself

Abstract

backgroundsThe PHILOS system is the most widely utilized device for the treatment of proximal humeral fractures. However, varus deformity of the humeral head, are frequently observed in PHILOS fixed patients. The primary etiology of these complications can be attributed to fixation instability. Consequently, any additional fixation devices that enhance stability may serve as alternative methods to mitigate the complications. Bone cement augmentation is an effective strategy for optimizing fixation stability in osteoporotic patients; however, the size limitation of the calcar screw in the traditional PHILOS plate restricts the volume of and the position bone cement. In response to this challenge, we presents a newly designed PHILOS plate featuring a single cannulated calcar screw. The biomechanical performance of this innovative device has been evaluated. A series of patients treated with this novel fixation device have been enrolled to assess its clinical efficacy.

methodsA proximal humerus model has been developed, and a simulation of proximal humeral fractures has been conducted using this model. Various operative techniques, including traditional and modified PHILOS fixation methods, as well as additional fixation devices, have been established. The biomechanical performance of these fixation strategies has been compared. Furthermore, a series of patients with proximal humeral fractures were included in this study. Fracture healing and the varus status of the humeral head were assessed to evaluate clinical efficacy during a six-month follow-up period.

resultsIn the biomechanical study, a comparison was made between the traditional PHILOS fixed model and three alternative models, revealing that the maximum deformation of the humeral head was significantly reduced in the latter. Notably, the fixation stability of the cement-augmented single calcar screw model surpassed that of the four-screw-augmented model. Furthermore, the maximum stress value observed in the model secured by a single calcar screw PHILOS plate was markedly lower than those recorded for other models. Additionally, 14 patients participated in this clinical series. All enrolled patients achieved optimal bone healing outcomes. The largest varus angle of the humeral head measured at 5°, with no instances of fixation failure reported.

conclusionThe newly designed PHILOS plate, featuring a cement-augmented single calcar cannulated screw, has demonstrated the ability to significantly reduce the risk of fixation failure and associated complications by optimizing the local biomechanical environment. Given its outstanding clinical outcomes observed in the current patient series, advocating for this fixation device holds considerable clinical significance in enhancing patients’ prognoses.

Indexed as

Bone CementsBone PlatesBone ScrewsFracture Fixation, InternalFracture HealingShoulder FracturesAgedAged, 80 and overBiomechanical PhenomenaFemaleHumansMaleMiddle AgedTreatment OutcomeBone Cements

Identifiers

PMID40616088
PMCPMC12232025

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked