ArticleJACC. Case reports2025
Worsening Heart Failure From Decreased Atrioventricular Synchronization Rate of a Leadless Pacemaker: Atrial Mechanical Oversensing.
Article in JACC. Case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAtrioventricular synchronous pacing with a leadless pacemaker is a therapy used in patients with atrioventricular block. However, atrial oversensing may cause an increase in heart rate, with resulting atrioventricular dyssynchrony. CASE SUMMARY: A 90-year-old woman, who was treated with a leadless pacemaker 2 years earlier for a complete atrioventricular block, developed congestive heart failure. The electrocardiogram revealed an increase in heart rate with atrioventricular dyssynchronous pacing and a decrease in atrioventricular synchronization rate. A manual atrial mechanical test indicated dyssynchronized atrioventricular pacing secondary to atrial mechanical oversensing. DISCUSSION: This case of heart failure exacerbation resulted from 1) the increase in heart rate with atrioventricular dyssynchrony caused by atrial mechanical oversensing and 2) the dyssynchronous pacing resulting from pacing-induced cardiomyopathy. TAKE-HOME MESSAGES: Atrioventricular synchronization can vary with changes in cardiac structure and hemodynamics. It is important to assess atrioventricular synchrony repeatedly in electrocardiograms or rate histograms in the device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.