Observational studyJMIR mHealth and uHealth2025
A New Wearable System for Personal Air Pollution Exposure Estimation: Pilot Observational Study.
Observational study in JMIR mHealth and uHealth, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- An On-Device Edge AI Agent for Reference-Free Self-Diagnosis of Low-Cost Multi-Pollutant Sensors.Sensors (Basel, Switzerland) · 2026Article
- Comparison of personal portable and fixed-site PMScientific reports · 2026Article
- An Adjustable Smart Ring to Monitor Pulse Rate and Peripheral Blood Oxygen Saturation.Annals of biomedical engineering · 2026Article
- Cancer and Environmental Xenobiotics: Mechanisms, Controversies, and Innovations.Journal of xenobiotics · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Air pollution is a major environmental cause of premature deaths, responsible for around 7 million deaths annually. In this context, personal air pollution exposure (PAPE), the product of pollutant concentration and minute ventilation (V'm), is a crucial measure for understanding individual health risks. Standard exposure techniques do not address the space-time variability of air pollution, both indoor and outdoor, and the intra- and intersubject variability in V'm. Objective: This study evaluates the feasibility of using a wearable body sensor network (BSN) to estimate PAPE in real-life settings, assess its capability to detect spatiotemporal variations in pollution levels, and compare inhaled dose estimates from the BSN with those from fixed monitoring stations and standard V'm values. The study also examines the system's usability. Methods: The system, a BSN capturing physiological (pulse rate [PR] and respiratory rate [RR]) and environmental data, including health-affecting pollutants (particulate matter [PM] 1, PM2.5, PM10, CO2, CO, total volatile organic compounds, and NO2), was tested in a 4.5 km walk in Milan by 20 healthy volunteers. PR and RR collected by the system were used, together with biometric data and forced vital capacity estimations, in a model for V'm estimation to compute PAPE. Pollution levels were compared between morning and afternoon measurements, as well as between indoor and outdoor settings. Results: Variations in RR were found among volunteers and at different locations for the same participant. Significant differences (P<.001) in pollutant concentrations were observed between morning and afternoon for CO2 (higher in the morning) and PM (higher in the afternoon). Spatial variability along the walking path was also detected, highlighting the system's high spatiotemporal resolution. Indoor environments showed high variability in CO2 and total volatile organic compounds, while outdoor settings exhibited elevated and variable PM levels. The mean PAPE to PM2.5 estimated with tabulated V'm and fixed station data was 13.31 (SD 4.16) μg while the one estimated with the BSN was 16.27 (SD 9.78) μg, 2.96 μg higher (22.3%; 95% CI -6.55 to 0.63; P=.05) than the former one, and with a broader IQR. Nevertheless, the 2 estimation methods show a good and strongly significant correlation (r=0.665; P<.001). The system's usability was generally rated as good. Conclusions: The BSN provides high-resolution spatiotemporal data on personal exposure, capturing differences in pollution levels dependent on time, location, and surrounding environment, along with individual physiological variations. It offers a more accurate estimation of inhaled dose in real-life settings, supporting personalized exposure assessments and potential applications in activity planning and complementing epidemiological research.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.