Evidence map›Paper›PMID 40610770›Full record

ArticleSe pu = Chinese journal of chromatography2025

[Fast determination of per- and polyfluoroalkyl substances in human serum by cold-induced phase separation coupled with liquid chromatography-tandem mass spectrometry].

Jian-di Wang, Yi-Wei Wang, Jia-Xin Wu, Zhi-Xiong Shi

Abstract readEnglish Abstract
In one paragraph

Article in Se pu = Chinese journal of chromatography, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jian-di WangSchool of Public Health,Capital Medical University,Beijing 100069,China.
Yi-Wei WangSchool of Public Health,Capital Medical University,Beijing 100069,China.
Jia-Xin WuSchool of Public Health,Capital Medical University,Beijing 100069,China.
Zhi-Xiong ShiSchool of Public Health,Capital Medical University,Beijing 100069,China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Per- and polyfluoroalkyl substances (PFASs) are a large group of synthetic chemicals that have been widely used in various industrial and commercial products owing to their unique physicochemical properties. However, accumulating evidence suggests that PFASs are persistent, transmissive over long distances, bioaccumulative, and toxic; consequently, their adverse effects on ecosystems and humans is of widespread concern. Serum is the most commonly used human matrix for assessing internal exposure to environmental pollutants, and several analytical methods have been developed to measure PFASs in sera. Current methods are generally fast, convenient, and robust; however, their pretreatment steps require large amounts of organic solvents and materials, such as solid-phase extraction cartridges and/or sorbents. In this study, a novel and low-cost analytical method based on cold-induced phase separation (CIPS) strategy was developed for the simultaneous determination of 31 legacy and emerging PFASs in serum. The core mechanism and distinctive feature of CIPS involves cooling an acetonitrile-water (ACN-water) mixture at a low temperature to produce two clear-cut layers: one with a high ACN proportion (the ACN layer) and an aqueous layer (water layer). Certain chemicals are significantly enriched in the ACN layer during cooling; at the same time, impurities, especially water-soluble impurities, remain in the aqueous layer. CIPS only requires the temperature to be varied, and no external impurities are introduced during pretreatment, which dramatically reduces material costs and avoids new impurities from intervening. Our method involves the following procedure: serum was drawn accurately (0.2 mL) into a 1.5 mL Eppendorf (EP) tube, 2 ng of each isotopically labeled internal standard was added, the mixture is vortexed, and 350 µL of ACN was added, followed by vortexing and ultrasonic extraction. Subsequently, 450 µL of water is added to adjust the volume proportion of ACN to 35% (the volume percentage of ACN in the total solution). The protein at the bottom of the tube was collected following centrifugation at 15 000 r/min for 10 min, and the supernatant was transferred to a 1 mL syringe. The syringe was frozen in a -20 ℃ refrigerator for 1 h to obtain the two layers, after which the upper layer (approximately 80-100 μL) containing ACN and the target compounds was finally transferred to a glass vial for instrumental analysis. Liquid chromatography coupled with triple quadrupole mass spectrometry augmented with electrospray ionization (LC-ESI-MS/MS) was used to quantify the PFASs. The analytes were separated using a C18 column, with methanol and 2 mmol/L of ammonium formate-H

Indexed as

Environmental PollutantsFluorocarbonsTandem Mass SpectrometryChromatography, LiquidCold TemperatureHumansPhase SeparationEnvironmental PollutantsFluorocarbonscold-inducedisotope dilutionliquid chromatography-tandem mass spectrometry (LC-MS/MS)per- and polyfluoroalkyl substances (PFASs)serum

Identifiers

PMID40610770
PMCPMC12231447

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.