Evidence map›Paper›PMID 40608988›Full record

ArticleACS applied materials & interfaces2025

Implantable Membrane Sensors and Long-Range Wireless Electronics for Continuous Monitoring of Stent Edge Restenosis.

Allison Bateman, Yuheng He, Chris Cherono, Jimin Lee, Nima Ghalichechian, Woon-Hong Yeo

Abstract read
In one paragraph

Article in ACS applied materials & interfaces, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Allison BatemanGeorge W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States.
Yuheng HeSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States.
Chris CheronoWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, GA 30332, United States.
Jimin LeeGeorge W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States.ORCID 0000-0002-8703-0979
Nima GhalichechianSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States.ORCID 0000-0002-2070-9864
Woon-Hong YeoGeorge W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States.ORCID 0000-0002-5526-3882

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous monitoring of vascular stent health is crucial for high-risk patients. Current approaches predominantly rely on inductive coupling, which limits the wireless reading distance and requires precise antenna alignment with implanted stents. Here, we present a long-range wireless electronic system that incorporates a low-resistance inductive stent fabricated via laser micromachining and electroplating of biocompatible metal films, forming a mechanically robust and conductive interface optimized for radar interrogation. A conformal, flexible capacitive pressure sensor is developed from soft dielectric elastomers and integrated within the stent's structure, enabling localized detection of hemodynamic pressure changes indicative of stent-edge restenosis. Computational modeling validates the antenna design as an effective radiator, while an in vitro study evaluates the performance of the stent-sensor assembly and wireless coupling. Our system successfully detected the stent from a distance of 50 cm, providing trackable localized pressure signals at 2 GHz for healthy stents as well as diagnostic capabilities for 50% stent-edge restenosis. This work establishes a new class of enhanced wireless stents, offering extended readout distances and real-time diagnostic capability, with broad implications for developing next-generation bioelectronic interfaces.

Indexed as

StentsWireless TechnologyHumansMonitoring, Physiologicconformable flexible pressure sensorimplantable bioelectronic sensormonostatic readingvascular stent monitoringwireless restenosis detection

Identifiers

PMID40608988
PMCPMC12314858

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.