Evidence map›Paper›PMID 40608622›Full record

ArticleRevista do Instituto de Medicina Tropical de Sao Paulo2025

An alternative real-time fluorescence reverse transcription loop-mediated isothermal amplification assay for the rapid detection of SARS-CoV-2.

Janisara Rudeeaneksin, Wiphat Klayut, Benjawan Phetsuksiri, Ballang Uppapong, Thanee Wongchai, Nuttagarn Chuenchom

Abstract read
In one paragraph

Article in Revista do Instituto de Medicina Tropical de Sao Paulo, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Janisara RudeeaneksinMinistry of Public Health, National Institute of Health, Department of Medical Sciences, Nonthaburi, Thailand.ORCID http://orcid.org/0009-0001-4859-7243
Wiphat KlayutMinistry of Public Health, National Institute of Health, Department of Medical Sciences, Nonthaburi, Thailand.ORCID http://orcid.org/0000-0002-4396-0410
Benjawan PhetsuksiriMinistry of Public Health, National Institute of Health, Department of Medical Sciences, Nonthaburi, Thailand.ORCID http://orcid.org/0000-0001-6507-2898
Ballang UppapongMinistry of Public Health, Administrative Office, Department of Medical Sciences, Nonthaburi, Thailand.ORCID http://orcid.org/0009-0004-1879-0618
Thanee WongchaiMinistry of Public Health, Mae Sot Hospital, Tak, Thailand.ORCID http://orcid.org/0009-0009-0765-7295
Nuttagarn ChuenchomMinistry of Public Health, Mae Sot Hospital, Tak, Thailand.ORCID http://orcid.org/0009-0001-0267-7993

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

COVID-19, caused by SARS-CoV-2 virus infection, remains a public health concern in many countries. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a rapid and cost-effective alternative test for COVID-19 diagnosis. In this study, we developed and evaluated a real-time RT-LAMP (rRT-LAMP) assay coupled with a melting curve analysis to detect SARS-CoV-2. The reaction was carried out in a real-time thermal cycler at 63 °C for 45 min to amplify the region of SARS-CoV-2 orf8; real-time monitoring of amplification was performed by fluorescence detection. The performance was assessed by comparing it to a real-time reverse transcription-polymerase reaction (rRT-PCR) as a reference. The rRT-LAMP could detect as few as 15 copies of SARS-CoV-2 RNA per reaction. Positive results appeared within 30 min, while the melting-temperature analysis could verify the amplification specificity. No positive results from non-SARS-CoV-2 templates and no mis-amplification were observed. The comparative analysis using 262 RNA extracted from nasopharyngeal swab samples revealed the overall accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) of the rRT-LAMP at 88.55% (95% CI: 77.52-100%), 84.13% (95% CI: 71.56-98.27%), 100% (95% CI: 78.38-100%), 100% (95% CI: 85.06-100%), and 70.87% (95% CI: 55.55-89.11%), respectively. The greatest sensitivity was as high as 98-100% for specimens with threshold rRT-PCR cycle (Ct) values of less than 30 cycles. Overall, this rRT-LAMP showed good performance for the rapid detection of SARS-CoV-2. It is proposed as a potential method for real-time amplification detection, offering increased laboratory capacity for SARS-CoV-2 testing in a cost-effective and timely manner.

Indexed as

COVID-19COVID-19 Nucleic Acid TestingMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesRNA, ViralSARS-CoV-2HumansReal-Time Polymerase Chain ReactionReproducibility of ResultsSensitivity and SpecificityTime FactorsRNA, Viral

Identifiers

PMID40608622
PMCPMC12204207

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.