ArticleJournal of neuroendovascular therapy2025
Proposal for Reducing the Operator Radiation Exposure Dose during 3D DSA Imaging under Carotid Artery Occlusion Tests (Matas and Allcock Test).
Article in Journal of neuroendovascular therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: 3D DSA performed under carotid artery occlusion tests (Matas and Allcock test) while the operator manually compresses the patient's carotid artery may be performed as a preoperative evaluation. However, few known studies have quantified the operator's radiation exposure dose during 3D DSA under carotid artery occlusion tests. In this study, we measured the changes in the operator's radiation exposure dose during such imaging under different protective measures and assessed alternative protective measures for hand exposure apart from protective gloves and the operator's head and neck orientation, proposing a new protection method. Methods: We measured changes in the operator's radiation exposure dose under different protective measures. Specifically, we measured changes in lens dose on the operator's head and neck orientation and the use of protective equipment. Furthermore, we evaluated alternative protective measures for hand exposure aside from protective gloves. Results: In all measurement points, the lower measured dose was recorded when protective measures were implemented. The measured doses to the left and right lenses varied depending on the usage of protective equipment and the orientation of the operator's head and neck. The lowest measured dose to both lenses was recorded when the protective equipment and ceiling-suspended shield were used, and the operator's head and neck were turned toward the subject. The hand dose was the lowest when protective gloves were used (316.9 μGy), representing a 72% reduction compared with unprotected conditions. When the neck guard or lead plate was inserted underneath the measurement points, the hand dose decreased by approximately 29% (884.3 μGy) and 43% (657.6 μGy), respectively, compared with unprotected conditions. Conclusion: Our findings confirmed that operator radiation exposure dose can be reduced through protective measures. The lens exposure dose was minimized when protective equipment and the ceiling-suspended shield were used, and the operator's head and neck were turned toward the subject. While the protective effect of the lead plates was lower than that of protective gloves-which can be challenging to use during manual compression-the method of inserting a lead plate beneath the patient table and bending it along the shoulder was identified as another useful alternative.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.