ArticleThe Iowa orthopaedic journal2025
3d-Printed One-Third Tubular Plates in an Ankle Fracture Model: A Biomechanical Study.
Article in The Iowa orthopaedic journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- 3D-Printed PLA/PETG Sterilizable Static/Dynamic Modular External Finger Fracture Fixator.Bioengineering (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: 3D printing is a fast-growing technology in orthopaedic surgery. The utility of 3D-printed orthopaedic implants has yet to be fully defined. This biomechanical study examines the capabilities of one such implant in an ankle fracture model. Methods: One-third tubular plates were 3D-printed using CFR-PLA (carbon fiber-reinforced polylactic acid) and PC (polycarbonate). Samples and stainless-steel controls were used to fix Weber B Sawbones fibula fracture models and analyzed with lateral bending, torsional, and torsional failure mechanical testing. Results: Stainless-steel one-third tubular plates were shown to have superior mechanical properties than the 3D-printed plates overall in valgus bending and with torsional failure. However, CFR-PLA 3D-printed plates demonstrated greater strength in torsion testing.. Conclusion: The differences in mechanical properties between stainless-steel one-third tubular plates and 3D-printed plates, while statistically significant, are likely not clinically significant. 3D-printed implants could be used as a viable alternative in ankle fracture fixation in the future. Clinical Relevance: To the authors' knowledge, this is the first biomechanical study performed on 3D-printed plates in an ankle fracture model. Given the increasing use of 3D printing, the findings described here could establish a basis for future areas of research.
Indexed as
Identifiers
40606723PMC12212315What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.