Evidence map›Paper›PMID 40604929›Full record

ArticleBMC oral health2025

Performance of two different artificial intelligence models in dental implant planning among four different implant planning software: a comparative study.

Pathompong Roongruangsilp, Walita Narkbuakaew, Pathawee Khongkhunthian

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Pathompong RoongruangsilpCenter of Excellence for Dental Implantology, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand.
Walita NarkbuakaewNational Electronics and Computer Technology Center, National Science and Technology Development Agency, Pathum Thani, Thailand.
Pathawee KhongkhunthianCenter of Excellence for Dental Implantology, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand. pathaweek@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe integration of artificial intelligence (AI) in dental implant planning has emerged as a transformative approach to enhance diagnostic accuracy and efficiency. This study aimed to evaluate the performance of two object detection models, Faster R-CNN and YOLOv7 in analyzing cross-sectional and panoramic images derived from DICOM files processed by four distinct dental imaging software platforms.

methodsThe dataset consisted of 332 implant position images derived from DICOM files of 184 CBCT scans. Three hundred images were processed using DentiPlan Pro 3.7 software (NECTEC, NSTDA, Thailand) for the development of Faster R-CNN and YOLOv7 models for dental implant planning. For model testing, 32 additional implant position images, which were not included in the training set, were processed using four different software programs: DentiPlan Pro 3.7, DentiPlan Pro Plus 5.0 (DTP; NECTEC, NSTDA, Thailand), Implastation (ProDigiDent USA, USA), and Romexis 6.0 (Planmeca, Finland). The performance of the models was evaluated using detection rate, accuracy, precision, recall, F1 score, and the Jaccard Index (JI).

resultsFaster R-CNN achieved superior accuracy across imaging modalities, while YOLOv7 demonstrated higher detection rates, albeit with lower precision. The impact of image rendering algorithms on model performance underscores the need for standardized preprocessing pipelines. Although Faster R-CNN demonstrated relatively higher performance metrics, statistical analysis revealed no significant differences between the models (p-value > 0.05).

conclusionsThis study emphasizes the potential of AI-driven solutions in dental implant planning and advocates the need for further research in this area. The absence of statistically significant differences between Faster R-CNN and YOLOv7 suggests that both models can be effectively utilized, depending on the specific requirements for accuracy or detection. Furthermore, the variations in imaging rendering algorithms across different software platforms significantly influenced the model outcomes. AI models for DICOM analysis should rely on standardized image rendering to ensure consistent performance.

Indexed as

Artificial IntelligenceDental ImplantsPatient Care PlanningSoftwareCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedRadiography, PanoramicDental ImplantsArtificial intelligenceCone-beam computed tomographyDeep learningDental implantMachine learning

Identifiers

PMID40604929
PMCPMC12217373

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.