Evidence map›Paper›PMID 40600702›Full record

ArticleJournal of clinical microbiology2025

A multicenter study to assess the performance of the point-of-care RT-PCR Cobas SARS-CoV-2 & Influenza A/B nucleic acid test for use on the Cobas Liat system in comparison with centralized assays across healthcare facilities in the United States.

Elissa M Robbins, Rasa Bertuzis, Ho-Chen Chiu, Lupe Miller, Christopher Noutsios

Abstract readMulticenter StudyComparative StudyEvaluation Study
In one paragraph

Article in Journal of clinical microbiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Elissa M RobbinsRoche Molecular Systems, Inc., Pleasanton, California, USA.ORCID 0000-0003-1737-3228
Rasa BertuzisRoche Molecular Systems, Inc., Pleasanton, California, USA.
Ho-Chen ChiuRoche Sequencing Solutions, Inc., Indianapolis, Indiana, USA.
Lupe MillerRoche Molecular Systems, Inc., Pleasanton, California, USA.
Christopher NoutsiosRoche Molecular Systems, Inc., Pleasanton, California, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Respiratory diseases can share many of the same symptoms, highlighting the need for timely and accurate differentiation to facilitate effective clinical management and reduce transmission. Compared with centralized testing, molecular point-of-care tests (POCTs) can provide a faster time to result. We evaluated the RT-PCR POCT Cobas® SARS-CoV-2 & Influenza A/B qualitative assay for use on the Cobas Liat system (the POC SARS-CoV-2 & Influenza A/B test) in nasal and nasopharyngeal swab samples from 10 diverse healthcare facilities in the United States. A composite comparator design consisting of three centralized tests was used to analyze severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), while performance vs a single centralized test was used for analysis of influenza A and B. Evaluations included performance stratified by sample type (prospective/retrospective and nasal/nasopharyngeal [paired by subject]), collection method (self/healthcare worker-collected [alternated and approximately balanced]), symptom status (symptomatic/asymptomatic), and SARS-CoV-2 vaccination status, as well as assay inclusivity and system ease of use. A total of 2,247 samples were tested. For SARS-CoV-2, the overall percent agreement (OPA) was 98.8% (95% confidence interval [CI]: 97.9, 99.3) in nasal swab samples and 99.0% (95% CI: 98.2, 99.4) in nasopharyngeal swab samples. Regression analysis showed that cycle threshold values from paired nasal and nasopharyngeal swab samples were highly correlated (correlation coefficient 0.83). The OPA was ≥99.5% (sample type dependent) and 100.0% for influenza A and B, respectively. The POC SARS-CoV-2 & Influenza A/B test was easy to use. These results support the use of the POCT in various sample types and by various operators in the intended-use setting. IMPORTANCE: This study highlights the benefits of RT-PCR point-of-care tests, namely comparable performance to centralized testing in multiple sample types and ease of use. Utilizing assays such as the POC Cobas SARS-CoV-2 & Influenza A/B test may improve the timely differentiation of respiratory diseases that share similar symptoms.

Indexed as

COVID-19COVID-19 Nucleic Acid TestingInfluenza A virusInfluenza B virusInfluenza, HumanPoint-of-Care TestingSARS-CoV-2AdultFemaleHumansMaleMiddle AgedMolecular Diagnostic TechniquesNasopharynxPoint-of-Care SystemsProspective Studiesemergency departmentinfluenza Ainfluenza Bnasalnasopharyngealoutpatientsperformancepoint of careprimary careSARS-CoV-2

Identifiers

PMID40600702
PMCPMC12345166

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked