ArticleBMC medical imaging2025
Automated 3D segmentation of the hyoid bone in CBCT using nnU-Net v2: a retrospective study on model performance and potential clinical utility.
Article in BMC medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- CAHA-Net: A novel MR image classification model based on DenseNet incorporating coordinate attention and hybrid augmentation.Scientific reports · 2026Article
- Fully automated 3D segmentation of periapical lesions on CBCT images using nnU-Net v2.BMC medical imaging · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThis study aimed to identify the hyoid bone (HB) using the nnU-Net based artificial intelligence (AI) model in cone beam computed tomography (CBCT) images and assess the model's success in automatic segmentation.
methodsCBCT images of 190 patients were randomly selected. The raw data was converted to DICOM format and transferred to the 3D Slicer Imaging Software (Version 4.10.2; MIT, Cambridge, MA, USA). HB was labeled manually using the 3D Slicer. The dataset was divided into training, validation, and test sets in a ratio of 8:1:1. The nnU-Net v2 architecture was utilized to process the training and test datasets, generating the algorithm weight factors. To assess the model's accuracy and performance, a confusion matrix was employed. F1-score, Dice coefficient (DC), 95% Hausdorff distance (95% HD), and Intersection over Union (IoU) metrics were calculated to evaluate the results.
resultsThe model's performance metrics were as follows: DC = 0.9434, IoU = 0.8941, F1-score = 0.9446, and 95% HD = 1.9998. The receiver operating characteristic (ROC) curve was generated, yielding an AUC value of 0.98.
conclusionThe results indicated that the nnU-Net v2 model achieved high precision and accuracy in HB segmentation on CBCT images. Automatic segmentation of HB can enhance clinicians' decision-making speed and accuracy in diagnosing and treating various clinical conditions. CLINICAL TRIAL NUMBER: Not applicable.