ArticleBMC medical imaging2025
Accelerating brain T2-weighted imaging using artificial intelligence-assisted compressed sensing combined with deep learning-based reconstruction: a feasibility study at 5.0T MRI.
Article in BMC medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundT2-weighted imaging (T2WI), renowned for its sensitivity to edema and lesions, faces clinical limitations due to prolonged scanning time, increasing patient discomfort, and motion artifacts. The individual applications of artificial intelligence-assisted compressed sensing (ACS) and deep learning-based reconstruction (DLR) technologies have demonstrated effectiveness in accelerated scanning. However, the synergistic potential of ACS combined with DLR at 5.0T remains unexplored. This study systematically evaluates the diagnostic efficacy of the integrated ACS-DLR technique for T2WI at 5.0T, comparing it to conventional parallel imaging (PI) protocols.
methodsThe prospective analysis was performed on 98 participants who underwent brain T2WI scans using ACS, DLR, and PI techniques. Two observers evaluated the overall image quality, truncation artifacts, motion artifacts, cerebrospinal fluid flow artifacts, vascular pulsation artifacts, and the significance of lesions. Subjective rating differences among the three sequences were compared. Objective assessment involved the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in gray matter, white matter, and cerebrospinal fluid for each sequence. The SNR, CNR, and acquisition time of each sequence were compared.
resultsThe acquisition time for ACS and DLR was reduced by 78%. The overall image quality of DLR is higher than that of ACS (P < 0.001) and equivalent to PI (P > 0.05). The SNR of the DLR sequence is the highest, and the CNR of DLR is higher than that of the ACS sequence (P < 0.001) and equivalent to PI (P > 0.05).
conclusionsThe integration of ACS and DLR enables the ultrafast acquisition of brain T2WI while maintaining superior SNR and comparable CNR compared to PI sequences. CLINICAL TRIAL NUMBER: Not applicable.