Evidence map›Paper›PMID 40596294›Full record

ArticleScientific reports2025

Clinical efficacy and biomechanical analysis of robotic internal fixation with percutaneous screws in the treatment of both-column acetabular fractures.

Xiangyu Qi, Xu Zhang, Qing Zhang, Yazhong Zhang, Shaolong Huang, Yongxiang Lv, Wenbo Li, Jun Qiang Wang, Ziqiang Zhu

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xiangyu Qi *Department of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.ORCID http://orcid.org/0009-0004-5674-3185
Xu Zhang *Department of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.ORCID http://orcid.org/0009-0004-8732-5541
Qing ZhangDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.
Yazhong ZhangDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.ORCID http://orcid.org/0000-0002-5144-1928
Shaolong HuangDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.ORCID http://orcid.org/0009-0008-3373-4146
Yongxiang LvDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.ORCID http://orcid.org/0009-0004-6057-9138
Wenbo LiDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.
Jun Qiang WangDepartment of Orthopaedic Trauma, Beijing Jishuitan Hospital, Beijing, 100035, People's Republic of China.
Ziqiang ZhuDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, China.ORCID http://orcid.org/0000-0002-9360-1790

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Both-column fractures of the acetabulum represent a particularly complex category of injury, with a high proportion necessitating surgical intervention. The most common surgical method is open reduction and internal fixation (ORIF), but this has problems like blood loss, long operations, and trauma after surgery. Robot-assisted percutaneous screw fixation is a minimally invasive treatment for both-column acetabular fractures. It has several clinical advantages, including precise screw positioning and stable performance. A comparison of the clinical efficacy of open reduction and internal fixation and robot-assisted percutaneous screws in the treatment of both-column acetabular fractures and biomechanical analyses were performed to compare the stability of the two fixation methods. Firstly, A finite element model was constructed for the purposes of analyzing both-column acetabular fractures, percutaneous screws, and reconstruction plates. Divided into four experimental groups: Group I: Acetabular anterior and posterior columns are screwed with a 6.5 mm percutaneous screw. Group II: The anterior column of the acetabulum is fixed with a 6.5 mm percutaneous screw, while the posterior column is fixed with a 7.3 mm percutaneous screw. Group III: Acetabular anterior and posterior columns are screwed with a 7.3 mm percutaneous screw. Group IV: Acetabular anterior and posterior columns are fixed with a 6-hole reconstruction plate. Each fracture group was tested under axial loads of 600 N to measure the hipbone's displacement, Von Mises stress (VMS), and its internal fixation components. Secondly, 36 patients with both-column acetabular fractures admitted from September 2020 to September 2023 were retrospectively analyzed; 19 of them in the ORIF group, and 17 of them in the robot-assisted group. A comparison of the operative time, duration of intraoperative fluoroscopy, intraoperative blood loss, incision length, Matta's radiological criteria, and Harris Hip Score (HHS) in two groups of patients. In terms of finite element analysis, the maximum VMS was observed for internal fixation in group II, and the minimum VMS was observed in group IV. The displacements of groups I, II, and III internal fixation were the same (approximately 1.00 mm), and the minimum internal fixation displacement was observed in group IV. The mean operating time in the ORIF group was 190.45 ± 25.40 min, the incision length was 20.56 ± 3.38 centimeters, the intraoperative bleeding was 958.73 ± 128.68 ml, and the fluoroscopy time was 55.18 ± 10.25 s. The mean operating time in the robotic group was 99.7 ± 18.8 min, with an incision length of 7.35 ± 0.56 cm, intraoperative bleeding of 50.00 ± 15.20 ml, and fluoroscopy time of 22.52 ± 14.50 s. There was a significant difference between the above data (P < 0.001). There was no significant difference in Matta's radiological criteria between the two groups. HHS at three months postoperatively and six months postoperatively were 77.81 ± 2.23 and 84.78 ± 4.65 in the ORIF group, and at three months postoperatively and six months postoperatively in the robotic group were 72.19 ± 1.85 and 82.28 ± 3.32. The use of robot-assisted percutaneous screw internal fixation for both-column acetabular fractures has been demonstrated to have similar fixed strength and therapeutic effect to that of ORIF plate fixation. In contrast, robot-assisted percutaneous screw therapy offers the advantages of minimal invasiveness and precision, thereby providing a novel therapeutic option for the clinical treatment of both-column acetabular fractures.

Indexed as

AcetabulumBone ScrewsFracture Fixation, InternalFractures, BoneRobotic Surgical ProceduresAdultBiomechanical PhenomenaFemaleFinite Element AnalysisHumansMaleMiddle AgedTreatment OutcomeBoth-column acetabular fracturesFinite element analysisPercutaneous screw.Robot

Identifiers

PMID40596294
PMCPMC12216115

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.