Evidence map›Paper›PMID 40594992›Full record

ArticleScientific reports2025

Use of bovine serum albumin might impair immunofluorescence signal in thick tissue samples.

Anna Chwastowicz, Artur Wolny, Magdalena Sobień, Marcin Barański, Jacek Tomczuk, Michał Szatkowski, Aleksandra Szredzka, Jakub Gołąb, Leszek Kaczmarek, Marzena Stefaniuk and 1 more

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Anna ChwastowiczDepartment of Immunology, Medical University of Warsaw, 5 Nielubowicza Street, Warsaw, 02-097, Poland.
Artur WolnyLaboratory of Imaging Tissue Structure and Function, Nencki Institute of Experimental Biology of Polish Academy of Sciences, 3 Pasteur Street, Warsaw, 02- 093, Poland.
Magdalena SobieńLaboratory of Neurobiology, BRAINCITY, Nencki Institute of Experimental Biology of Polish Academy of Sciences, 3 Pasteur Street, Warsaw, 02-093, Poland.
Marcin BarańskiLaboratory of Neurobiology, BRAINCITY, Nencki Institute of Experimental Biology of Polish Academy of Sciences, 3 Pasteur Street, Warsaw, 02-093, Poland.
Jacek TomczukDepartment of Immunology, Medical University of Warsaw, 5 Nielubowicza Street, Warsaw, 02-097, Poland.
Michał SzatkowskiDepartment of Immunology, Medical University of Warsaw, 5 Nielubowicza Street, Warsaw, 02-097, Poland.
Aleksandra SzredzkaDepartment of Immunology, Medical University of Warsaw, 5 Nielubowicza Street, Warsaw, 02-097, Poland.
Jakub GołąbDepartment of Immunology, Medical University of Warsaw, 5 Nielubowicza Street, Warsaw, 02-097, Poland.
Leszek KaczmarekLaboratory of Neurobiology, BRAINCITY, Nencki Institute of Experimental Biology of Polish Academy of Sciences, 3 Pasteur Street, Warsaw, 02-093, Poland.
Marzena StefaniukLaboratory of Neurobiology, BRAINCITY, Nencki Institute of Experimental Biology of Polish Academy of Sciences, 3 Pasteur Street, Warsaw, 02-093, Poland.
Paweł MatrybaDepartment of Immunology, Medical University of Warsaw, 5 Nielubowicza Street, Warsaw, 02-097, Poland. p.matryba@nencki.edu.pl.

Funding

Narodowe Centrum Nauki 2019/35/B/NZ4/04077Narodowe Centrum Nauki UMO-2019/35/N/NZ6/04043Warszawski Uniwersytet Medyczny 1M19/4/M/MG/N/21
6 · The paper itself

Abstract

Significant progress in microscopic imaging techniques allowed transition from predominantly qualitative methods to a powerful tool for quantitative research, driven by improved instrumentation and computational power. Furthermore, previously limited to thin, laser-permeable tissue sections, imaging techniques have been revolutionized by the advent of tissue optical clearing. This innovation enables the visualization and quantitative analysis of entire organs and even whole bodies at cellular resolution. However, achieving high-quality imaging depends not only on the transparency of the tissue preparation but also on precise immunofluorescence labeling to ensure accurate signal detection and reliable study outcomes. In this study, we evaluated whether various reagents that are typically applied during the tissue blocking step prior to immunofluorescence staining affect the quality of the obtained image in thick and optically cleared samples. We demonstrate that the commonly employed tissue blocking step does not improve imaging conditions and even can substantially degrade fluorescence signal quality, particularly in large, optically cleared tissues such as whole mouse brain hemispheres.

Indexed as

Fluorescent Antibody TechniqueSerum Albumin, BovineAnimalsBrainMiceMicroscopy, FluorescenceSerum Albumin, BovineBovine serum albuminBSAConfocal microscopyImmunofluorescenceTissue clearing

Identifiers

PMID40594992
PMCPMC12215187

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.