ArticleScientific reports2025
The safety and efficacy of transarterial embolization with detachable coils for complex visceral artery aneurysm.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Detachable coils grant controlled deployment, retrieval, and repositioning until desired placement is achieved for complex visceral artery aneurysms (VAAs), but a detailed investigation is needed for its clinical application. Between June 2018 and September 2020, 28 patients with 31 complex VAAs successfully treated with detachable coils in two hospitals were retrospectively analyzed. The technical success rate reached 100%. Then, 96.8% (30/31) of the afferent arteries and 94.9% (75/79) of the efferent branches were patent without occlusion after the procedure. At the last follow-up, 77.4% and 12.9% of aneurysms were graded as class I and class IIIa, respectively, according to the Modified Raymond-Roy Occlusion Classification. Compared to immediately after the procedure, the number of aneurysms decreased in classes II, IIIa, and IIIb, whereas the number of class I aneurysms significantly increased from 18 to 24 at the last follow-up. Bleeding was not identified in any patients, but three patients (two with abdominal pain and one asymptomatic) developed ischemic complications of either splenic or renal infarction. Overall, transarterial embolization with detachable coils was safe and effective for treating complex VAAs, and the procedure should be performed with caution to avoid ischemic complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.