Evidence map›Paper›PMID 40593251›Full record

ArticleScientific reports2025

Physico-mechanical characterization of 3D-printed PLGA for patient-specific resorbable implants in craniofacial surgery.

Dimitri Kulker, Julie Pepin, Benoit Rosa, Boris Laure, Mathieu Venin, Jordan Biglione, Arnaud Pare

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dimitri KulkerDepartment of Maxillofacial and Plastic Surgery, Trousseau Hospital, University Hospital of Tours, Tours, France. d.kulker@chu-tours.fr.
Julie PepinLaboratory of Mechanics Gabriel Lamé, INSA CVL, University of Tours, University of Orléans, 7 Avenue Marcel Dassault, 37200, Tours, France.
Benoit RosaLaboratory of Mechanics Gabriel Lamé, INSA CVL, University of Tours, University of Orléans, 7 Avenue Marcel Dassault, 37200, Tours, France.
Boris LaureDepartment of Maxillofacial and Plastic Surgery, Trousseau Hospital, University Hospital of Tours, Tours, France.
Mathieu VeninLaboratory of Mechanics Gabriel Lamé, INSA CVL, University of Tours, University of Orléans, 7 Avenue Marcel Dassault, 37200, Tours, France.
Jordan BiglioneLaboratory of Mechanics Gabriel Lamé, INSA CVL, University of Tours, University of Orléans, 7 Avenue Marcel Dassault, 37200, Tours, France.
Arnaud PareDepartment of Maxillofacial and Plastic Surgery, Trousseau Hospital, University Hospital of Tours, Tours, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patient-specific implant (PSI) has optimized the management for a wide range of complex craniofacial deformity over the past years by increasing the accuracy of surgical procedures and lowering the operating time. In hypertelorism (HTO) surgery particularly, the orbital bone repositioning is nowadays guided by patient-specific bone fixation plates that are usually made from non-resorbable alloplastic material (e.g., titanium). Developing resorbable personalized plates could be a relevant alternative to overcome the well-known drawbacks of titanium plates such as infection, exposure or even the lack of bone growth which is detrimental in pediatric patients. This study investigated the mechanical and structural characteristics of poly(lactic-co-glycolic acid) (PLGA) PSI as resorbable materials for HTO surgery. We assessed the feasibility of printing PLGA PSI by Fused Deposition Modeling additive manufacturing (FDM). The geometrical and the mechanical properties of the 3D-printed device were compared with standard resorbable plates and analyzed after sterilization process (i.e., hydrogen peroxide gas plasma). The Young's modulus was greater than the standard resorbable plates while a decrease of 36% (p = 0.004) after the sterilization was observed. The sterilization also induced a plate deformation with an increase of 0.27 mm in Z-axis and a decrease of 0.8 mm in Y-axis due to annealing effect. Compared to the design, the PLGA PSI were successfully 3D-printed with a maximum deviation of 0.1 mm, making our custom-made plate promising for personalized craniofacial applications. Further investigations on the sterilization process must be considered in view of its mechanical and structural impact on resorbable PSI.

Indexed as

Absorbable ImplantsPolylactic Acid-Polyglycolic Acid CopolymerPrinting, Three-DimensionalBone PlatesElastic ModulusHumansMaterials TestingSkullPolylactic Acid-Polyglycolic Acid Copolymer

Identifiers

PMID40593251
PMCPMC12214947

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked