Evidence map›Paper›PMID 40593161›Full record

ArticleCalcified tissue international2025

Feasibility of 100 kV Low-voltage Bone Mineral Density Measurement with Quantitative CT: Phantom and Clinical Research.

Yali Li, Dan Jin, Yan Zhang, Mengze Zhang, Zhen Qian, Chenyu Jiang, Ming Ni, Suwei Liu, Huishu Yuan

Abstract read
PubMed Publisher
In one paragraph

Article in Calcified tissue international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yali Li *Department of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China.ORCID http://orcid.org/0000-0002-5320-4360
Dan Jin *Department of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China.
Yan Zhang *Department of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China.
Mengze ZhangThe Institute of Intelligent Diagnostics, Beijing United-Imaging Research Institute of Intelligent Imaging, Building 3-4 F, 9 Yongteng N. Road, Beijing, 100080, China.
Zhen QianThe Institute of Intelligent Diagnostics, Beijing United-Imaging Research Institute of Intelligent Imaging, Building 3-4 F, 9 Yongteng N. Road, Beijing, 100080, China.
Chenyu JiangDepartment of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China.
Ming NiDepartment of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China.
Suwei LiuDepartment of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China.
Huishu YuanDepartment of Radiology, Peking University Third Hospital, 49 Huayuan N Rd, Haidian, Beijing, 100191, China. huishuy@bjmu.edu.cn.

Funding

Beijing New Health Industry Development Foundation No. XM2020-02-006National Natural Science Foundation of China 82171927Natural Science Foundation of Beijing Municipality No. 7212126
6 · The paper itself

Abstract

To investigate the feasibility and accuracy of 100 kV low-voltage quantitative CT (QCT) for bone mineral density (BMD) measurement using the European Spine Phantom and patients. The accuracy and precision of the BMD measurements were assessed using relative measurement error (RME%), coefficient of variation (CV%), root mean square standard deviation (RMS-SD), and root mean square CV (RMS-%CV). Linear regression and Bland‒Altman analyses were used to assess the agreement between 100 and 120 kV QCT-based BMD measurements. The diagnostic performance of 100 kV QCT for osteoporosis was evaluated using receiver operating characteristic curve analysis. For the ESP, the mean BMD values at 100 kV were slightly greater than those at 120 kV, mainly due to small inaccuracies remaining in the BMD calibration process. The RME% values for all vertebrae were -3.31 to 15.00% at 100 kV and -9.34 to 3.06% at 120 kV, falling within ± 10% at 120 kV but within 0‒15% at 100 kV. The CV% and RMS-%CV values decreased as the BMD increased with increasing tube voltage, while the RMS-SD exhibited a decreasing trend. For patients, linear regression and Bland‒Altman analyses revealed good agreement between 120 and 100 kV (R

Indexed as

Bone DensityOsteoporosisTomography, X-Ray ComputedAdultAgedAged, 80 and overFeasibility StudiesFemaleHumansMaleMiddle AgedPhantoms, ImagingReproducibility of ResultsSpineBone mineral densityEuropean spine phantomLow-voltageQuantitative computed tomographyRadiation dose

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.