Evidence map›Paper›PMID 40591001›Full record

ArticleWorld journal of urology2025

Ho: YAG and thulium fiber lasers exhibit comparable temperature distribution: an in vitro evaluation of thermal safety distances for endourological applications-section of EAU endourology.

Daniele Robesti, Christian Corsini, Davide Perri, Jia-Lun Kwok, Arman Tsaturyan, Carlotta Nedbal, Luca Villa, Nicola Fossati, Andrea Gallina, Ioannis Kartalas Goumas and 6 more

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in World journal of urology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Daniele RobestiVita-Salute San Raffaele University, Milan, Italy.
Christian CorsiniVita-Salute San Raffaele University, Milan, Italy.
Davide PerriDivision of Urology, Sant'Anna Hospital, Via Ravona 20, 22042, San Fermo Della Battaglia, Italy.
Jia-Lun KwokDepartment of Urology, Tan Tock Seng Hospital, Singapore, Singapore.
Arman TsaturyanDepartment of Urology and Andrology, Astana Medical University, Astana, Kazakhstan.
Carlotta NedbalUrology Unit, Azienda Ospedaliero-Universitaria Delle Marche, Università Politecnica Delle Marche, Ancona, Italy.
Luca VillaVita-Salute San Raffaele University, Milan, Italy.
Nicola FossatiDepartment of Surgery, Service of Urology, Ente Ospedaliero Cantonale (EOC), Lugano, Switzerland.
Andrea GallinaDepartment of Surgery, Service of Urology, Ente Ospedaliero Cantonale (EOC), Lugano, Switzerland.
Ioannis Kartalas GoumasDepartment of Urology, Istituto Clinico Beato Matteo, Vigevano, Italy.
Andrea SaloniaVita-Salute San Raffaele University, Milan, Italy.
Vineet GauharDepartment of Urology, Ng Teng Fong General Hospital, National University Health System, Singapore, Singapore.
Bhaskar K SomaniDepartment of Urology, University Hospital Southampton, Southampton, UK.
Olivier TraxerDepartment of Urology, Tenon Hospital, Hôpitaux Universitaires Paris-Est, AP-HP, Université Pierre et Marie Curie Paris, Paris, France.
Paola Saccomandi *Department of Mechanical Engineering, Politecnico di Milano, 20156, Milan, Italy.
Eugenio Ventimiglia *Department of Surgical Sciences, Uppsala University, Uppsala, Sweden. eugenio.ventimiglia@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe concept of thermal safety distance upon laser activation has been recently introduced. We aimed to compare the thermal safety distance of Ho: YAG and thulium fiber laser (TFL) activation at different setups using an in vitro model.

methodsThe experimental setup used a glass pipette with an open roof bulb in a 37 °C water bath to simulate a renal calyx. We analyzed two scenarios: (1) Laser activation without irrigation; (2) Laser activation at the center of the calyx with irrigation (saline at 40 cmH

resultsWe observed no differences both in recorded temperature values and in their temporal/spatial distribution (all p > 0.05). The safety threshold was not exceeded for either Ho: YAG or TFL lasers at 5 W, 10 W, and 20 W when irrigation was applied, with no statistically significant difference in safety distance between the two lasers (p > 0.05). Similarly, without irrigation, only the 20 W (Ho: YAG: 0.93 ± 0.11 mm, TFL: 0.84 ± 0.09 mm) settings exceeded the safety threshold, and no significant difference in safety distance was found between the lasers (p > 0.05).

conclusionsNo differences in safety distance were observed between TFL and Ho: YAG lasers, regardless of irrigation or power settings. It is recommended for both lasers to remain below 20 W in absence of proper irrigation.

Indexed as

Kidney CalicesLasers, Solid-StateThuliumHumansIn Vitro TechniquesTemperatureThuliumIn vitro modelLaser temperatureStoneThermal doseThermal safety

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.