Evidence map›Paper›PMID 40590013›Full record

ArticleEuropean journal of radiology open2025

High-pitch photon-counting detector computed tomography angiography of the coronary arteries: Qualitative and quantitative evaluation of monoenergetic image reconstructions.

Andreas Strassl, Francesco Lauriero, Maria Alejandra Rueda, Christian Wassipaul, Michael Weber, Christian Loewe, Dietrich Beitzke, Lucian Beer

Abstract read
In one paragraph

Article in European journal of radiology open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Andreas StrasslDivision of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1090, Austria.
Francesco LaurieroDivision of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1090, Austria.
Maria Alejandra RuedaDivision of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1090, Austria.
Christian WassipaulDivision of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1090, Austria.
Michael WeberDivision of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1090, Austria.
Christian LoeweDivision of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1090, Austria.
Dietrich BeitzkeDivision of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1090, Austria.
Lucian BeerDivision of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1090, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Dual-source photon-counting detector computed tomography (PCDCT) offers the opportunity to perform cardiac examinations within one beat and simultaneously the acquisition of spectral information. This study, evaluated subjective and objective image quality of virtual monoenergetic image (VMI) reconstructions using data from a first-generation, dual-source PCDCT scanner, operated in high-pitch scanning mode. Methods: We retrospectively included 30 patients who underwent a clinically indicated CTA of the coronary arteries. VMI were reconstructed at five different energy levels. Subjective image quality was assessed by three radiologists according to a four-point Likert scale for four different quality features. To evaluate objective image quality, SNR and CNR were calculated via ROIs placed in the aorta, coronary arteries, myocardium, pectoral muscle, and epicardial fat. Results: VMI at 40, 50, 60, and 70 keV showed equal mean scores (4/4) for subjective vascular contrast, followed by 80 keV reconstructions with a mean score of 3/4. The 40 keV reconstruction yielded the lowest range (3-4) in Likert scores and highest percentage of reader agreement (80 %). Minor differences in subjective image noise, sharpness, and plaque visualization were observed with positive trends toward higher keV levels. SNR and CNR were superior for 40 keV, with a mean of 34.8 ± 1.7HU and 45.4 ± 2.7HU, respectively. Mean applied contrast volume was 65 ml, resulting in a mean CT value of 1150HU for 40 keV VMI. Conclusion: First-generation PCDCT-derived VMI at 40 and 50 keV offer satisfying subjective and objective image quality, even when acquired in high-pitch scanning mode.

Indexed as

Contrast mediaCoronary artery diseaseCoronary CTAPhoton-counting detector CTVirtual monoenergetic image

Identifiers

PMID40590013
PMCPMC12206059

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.