ArticleJournal of cardiothoracic surgery2025
Infective endocarditis with perivalvular abscess following sutureless valve implantation, successfully treated with aortic root reconstruction and biological Bentall procedure.
Article in Journal of cardiothoracic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Infective Endocarditis in Perceval Sutureless Valves: Incidence, Diagnostic Challenges, and Management: An Expert Opinion Review.Diagnostics (Basel, Switzerland) · 2026Review
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAortic valve prosthetic infections can lead to the spread of infection, causing annular abscesses and annular destruction, which may require annular reconstruction and aortic root replacement. Reports on the infection and reoperation of sutureless valves are rare. Here, we present a case of infection involving a Perceval sutureless valve, which led to an annular abscess. CASE PRESENTATION: We report the case of a 73-year-old woman who had previously undergone sutureless valve implantation for severe stenosis of a bicuspid aortic valve. Approximately 23 months after surgery, the patient developed recurrent Methicillin-resistant Staphylococcus aureus bacteremia and was admitted to the hospital. Following a thorough assessment, she was diagnosed with a prosthetic valve infection and an annular abscess, necessitating surgical intervention. Intraoperatively, significant annular destruction was evident after the valve was removed. The aortic root was reconstructed with a bovine patch and Bentall surgery was accomplished using a composite graft consisting of a biological valve and a Valsalva graft. The patient was discharged in good general condition with no significant post-operative complications.
conclusionsOne of the issues with using a Perceval valve is that in the event of infection, it can lead to the spread of infection from the aortic root to the left ventricular outflow tract, potentially requiring extensive debridement and aortic root replacement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.