Evidence map›Paper›PMID 40586847›Full record

ArticleEpilepsia2025

The impact of EEG preprocessing parameters on ultra-low-power seizure detection.

Patrick Reisinger, Jonathan Larochelle, Ciamak Abkai, Sotirios Kalousios, Nico Zabler, Matthias Dümpelmann, Andreas Schulze-Bonhage, Peter Woias, Laura Comella

Abstract read
In one paragraph

Article in Epilepsia, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Patrick ReisingerPrecisis GmbH, Research & Development, Heidelberg, Germany.ORCID https://orcid.org/0000-0003-2560-708X
Jonathan LarochelleDepartment of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0009-0005-8096-2537
Ciamak AbkaiPrecisis GmbH, Research & Development, Heidelberg, Germany.ORCID https://orcid.org/0000-0001-6741-0053
Sotirios KalousiosEpilepsy Center, Department of Neurosurgery, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0009-0007-7072-9576
Nico ZablerDepartment of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0000-0002-4406-1863
Matthias DümpelmannDepartment of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0000-0002-1476-7777
Andreas Schulze-BonhageEpilepsy Center, Department of Neurosurgery, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0000-0003-2382-0506
Peter WoiasDepartment of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0000-0002-4715-6032
Laura ComellaDepartment of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.ORCID https://orcid.org/0000-0001-8283-1454

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveClosed-loop neurostimulation is a promising treatment for drug-resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). Although many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis of the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels.

methodsWe analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions, and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event-based metrics, we evaluated seizure detection performance of a state-of-the-art convolutional neural network (CNN) via the Seizure Community Open-Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed-effects models. Energy consumption was analyzed using an ultra-low-power microcontroller.

resultsReducing the sampling rate from 256 to 64 Hz decreased sensitivity (p = .015) and false detections per hour (FD/h; p = .002). Larger windows reduced FD/h between 1 s and all other sizes (all p < .001). Lower digital resolution decreased sensitivity between 16 and 8 bits (p = .007). Using one EEG channel instead of four decreased sensitivity (p < .001) and increased detection delay (p = .020), but also reduced FD/h (p = .005). Reducing the sampling rate to 64 Hz lowered CNN energy consumption from 49.15 to 17.26 μJ/s, and using one channel reduced it from 79.04 to 31.63 μJ/s. SIGNIFICANCE: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed-loop neurostimulation devices to further advance the treatment of drug-resistant focal epilepsy.

Indexed as

Drug Resistant EpilepsyElectroencephalographyEpilepsies, PartialSeizuresSignal Processing, Computer-AssistedAdolescentAdultFemaleHumansMaleMiddle AgedNeural Networks, ComputerYoung Adultclosed‐loop neurostimulationdrug‐resistant focal epilepsyEEGenergy consumptionneural networksseizure detection

Identifiers

PMID40586847
PMCPMC12605768

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.