Evidence map›Paper›PMID 40586669›Full record

ArticleTranslational vision science & technology2025

Assessment of Diffractive Intraocular Lenses Using Near-Infrared Light: A Critical Evaluation.

Ricardo Elsner, Mario Gerlach, Sebastian Bohn, Jan Sievers, Heinrich Stolz, Rudolf F Guthoff, Oliver Stachs, Karsten Sperlich

Abstract read
In one paragraph

Article in Translational vision science & technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Basic Optics Underlying Current Intraocular Lenses.Journal of clinical medicine · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ricardo ElsnerDepartment of Ophthalmology, Rostock University Medical Center, Rostock, Germany.
Mario GerlachCarl Zeiss Meditec AG, ZEISS Group, Berlin, Germany.
Sebastian BohnDepartment of Ophthalmology, Rostock University Medical Center, Rostock, Germany.
Jan SieversInstitute of Physics, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany.
Heinrich StolzInstitute of Physics, University of Rostock, Rostock, Germany.
Rudolf F GuthoffDepartment of Ophthalmology, Rostock University Medical Center, Rostock, Germany.
Oliver StachsDepartment of Ophthalmology, Rostock University Medical Center, Rostock, Germany.
Karsten SperlichDepartment of Ophthalmology, Rostock University Medical Center, Rostock, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: After cataract surgery, near-infrared (NIR) light-based optical devices are commonly used for in vivo vision quality assessment, using wavefront sensors and double-pass techniques. This study investigates the diffraction efficiencies and orders of the AT LISA tri 839MP (Carl Zeiss Meditec AG, Berlin, Germany) under visible and NIR illumination, highlighting challenges in using NIR-based devices to evaluate diffractive intraocular lenses (IOLs). Methods: This study uses an optical bench system to generate in vitro through focus intensity data and compares the results to an optics simulation using the manufacturer's theoretically designed diffractive surface topography of the investigated trifocal IOL instead of possibly error-prone measured topography data. Results: For visible light, through-focus curve intensities and energy efficiencies behaved as expected. However, under NIR light, near and intermediate foci showed significantly reduced intensities compared to the far focus. Energy efficiency measurements indicate suboptimal performance of the near and intermediate foci with NIR light. Under these conditions, the investigated trifocal IOL became almost monofocal. Conclusions: The study demonstrates the wavelength-dependent behavior of the diffractive IOL, emphasizing the risks of inaccurate assessments when using NIR-based devices. It highlights the need for visible-light-based techniques for accurate evaluation and the importance of using precise surface topography data in simulations. Translational Relevance: This research bridges the gap between basic research and clinical care by showing that vision assessments performed with NIR-light inaccurately evaluate diffractive IOLs, guiding clinicians toward visible-light techniques for accurate vision assessment.

Indexed as

Infrared RaysLenses, IntraocularHumansLight

Identifiers

PMID40586669
PMCPMC12212444

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.