Evidence map›Paper›PMID 40583720›Full record

ArticleJournal of proteome research2025

Enhancing Tandem MS Sensitivity and Peptide Identification via Ion Preaccumulation in an Orbitrap Mass Spectrometer.

Florian Harking, Ulises H Guzman, Julia Kraegenbring, Hamish Stewart, Konstantin Aizikov, Heiner Koch, Kyle L Fort, Alexander Harder, Jesper V Olsen

Abstract read
In one paragraph

Article in Journal of proteome research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Florian HarkingNovo Nordisk Foundation Center for Protein Research, University of Copenhagen, Copenhagen 2200, Denmark.
Ulises H GuzmanNovo Nordisk Foundation Center for Protein Research, University of Copenhagen, Copenhagen 2200, Denmark.
Julia KraegenbringThermo Fisher Scientific, Bremen 28199, Germany.
Hamish StewartThermo Fisher Scientific, Bremen 28199, Germany.ORCID 0009-0000-1510-4353
Konstantin AizikovThermo Fisher Scientific, Bremen 28199, Germany.
Heiner KochThermo Fisher Scientific, Bremen 28199, Germany.
Kyle L FortThermo Fisher Scientific, Bremen 28199, Germany.
Alexander HarderThermo Fisher Scientific, Bremen 28199, Germany.
Jesper V OlsenNovo Nordisk Foundation Center for Protein Research, University of Copenhagen, Copenhagen 2200, Denmark.ORCID 0000-0002-4747-4938

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-throughput mass spectrometry-based proteomics has gained increasing interest for both academic and industrial applications. As implementation of faster gradients has facilitated higher sample throughput, mass spectrometers must adapt to shorter analysis times by enhancing the scanning speed and sensitivity. For Orbitrap mass spectrometers, faster scan rates are constrained by the need for sufficient ion accumulation time, particularly given the limitations on the duty cycle at high repetition rates, and transient length, which determines analyzer sensitivity and resolving power. In this context, implementing alternative ion scheduling and better ion signal-processing strategies is needed to unleash the speed of these instruments. Here, we introduce a new scanning strategy termed preaccumulation, which enables the storage of ions in the bent flatapole in parallel to the operation of the C-trap/IRM, leading to a significant improvement in ion beam utilization and enabling for the first time scanning speeds of ∼70 Hz on hybrid Orbitrap instruments. The combination of preaccumulation and increased scan speeds notably enhances peptide and protein group identifications for short LC gradients and improves sensitivity for high-throughput applications. These benefits were further amplified when coupled with the full mass range phase-constrained spectrum deconvolution method (ΦSDM), especially for fast, lower-resolution Orbitrap measurements with short LC gradients. Overall, we demonstrate that preaccumulation of ions in the bent flatapole offers distinct advantages, particularly for conditions with reduced signal input. Since no hardware changes are required, this approach is highly attractive for Orbitrap mass spectrometers operated with fast MS/MS acquisition methods.

Indexed as

PeptidesProteomicsTandem Mass SpectrometryChromatography, LiquidIonsIonsPeptidesbent flatapoleOrbitrappreaccumulationscanning speedΦSDM

Identifiers

PMID40583720
PMCPMC12322952

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.