Evidence map›Paper›PMID 40583112›Full record

ArticleBJU international2026

Flexible and navigable suction access sheaths: what size stone particles can be cleared?

Richard Menzies-Wilson, Jessica Williams, Koushikk Ayyappan, Thijs Ruiken, Candace Rhodes, Ben Turney

Abstract read
In one paragraph

Article in BJU international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Richard Menzies-WilsonNuffield Department of Surgery, University of Oxford, Oxford, UK.ORCID 0000-0002-3449-8594
Jessica WilliamsBoston Scientific Corporation, Marlborough, MA, USA.
Koushikk AyyappanNuffield Department of Surgery, University of Oxford, Oxford, UK.
Thijs RuikenNuffield Department of Surgery, University of Oxford, Oxford, UK.
Candace RhodesBoston Scientific Corporation, Marlborough, MA, USA.ORCID 0000-0003-3653-789X
Ben TurneyNuffield Department of Surgery, University of Oxford, Oxford, UK.ORCID 0000-0003-0885-6404

Funding

Boston Scientific Corporation
6 · The paper itself

Abstract

objectivesTo perform benchtop experiments on flexible and navigable suction (FANS) ureteric access sheaths (UASs) to determine the clearance capabilities for various stone sizes when paired with different-sized ureteroscopes.

methodsQuartz stones were used as a surrogate for renal stones. Stone samples were created to simulate the range of particle sizes produced by 'dusting' a 1-cm calcium oxalate monohydrate stone. The stone mixture was introduced into an open vial at a 30° angle in aliquots every 3 min over the course of 30 min, mimicking their gradual production by lasertripsy. This benchtop model focused on the effects of geometry (between FANS access sheath and ureteroscope) and suction, excluding complex fluid flow. An 11/13-F ClearPetra® FANS UAS with an indwelling ureteroscope was free to move in the vial and targeted visible stones. The vial was intermittently filled to 40 mL with water and emptied using 200-mmHg suction. The experiment had two arms: (1) a permanently indwelling ureteroscope in the FANS UAS to mimic continuous lasering with aspiration and (2) intermittent withdrawal of the ureteroscope to mimic pausing lasering to clear larger fragments through the empty FANS sheath lumen. Three ureteroscope sizes were used: 9.5-F (Lithovue™), 7.5 F (PUSEN) and 6.3 F (Hugemed). The experiment was performed four times for each ureteroscope. [Correction added on 4 July 2025, after first online publication: In the preceding sentence, "three" has been corrected to "four" in this version.]

resultsWith a permanently indwelling 9.5-F ureteroscope, the FANS UAS cleared 64% of the overall stone mass but became blocked after an average of 21 min. Intermittent withdrawal of the ureteroscope cleared all stones. With indwelling 7.5-F and 6.3-F ureteroscopes, the FANS UAS did not become blocked and completely cleared stones of up to 500 μm and 2 mm, respectively.

conclusionsWithout withdrawing the ureteroscope (potentially allowing continuous lasertripsy), it is possible to continuously aspirate small fragments alongside a 7.5-F and a 6.3-F ureteroscope in an 11/13-F FANS UAS. Intermittent withdrawal of a ureteroscope from the FANS UAS allows complete stone clearance.

Indexed as

Kidney CalculiUreterUreteroscopyBenchmarkingIn Vitro TechniquesLithotripsy, LaserParticle SizeSuctionUreteroscopesclearanceflexible and navigable suction access sheathsSFRstone‐free rateureteroscopy

Identifiers

PMID40583112
PMCPMC12950927

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.