Evidence map›Paper›PMID 40577487›Full record

ArticleClinical implant dentistry and related research2025

A Comparative Study on the Accuracy of Implant Placement Using 3D-Printed and Milled Guides Without Metal Sleeves.

Juan Ballesteros, Solange Vásquez, Marta Revilla-León, Miguel Gómez-Polo

Abstract readComparative Study
In one paragraph

Article in Clinical implant dentistry and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Bioinformation · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Juan BallesterosPrivate Practice in Cordoba, Spain.
Solange VásquezSchool of Dentistry, Complutense University of Madrid, Madrid, Spain.ORCID https://orcid.org/0000-0002-5130-1060
Marta Revilla-LeónDepartment of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.ORCID https://orcid.org/0000-0003-2854-1135
Miguel Gómez-PoloAdvanced Implant-Prosthesis Postgraduate Program, Complutense University of Madrid, Madrid, Spain.ORCID https://orcid.org/0000-0001-8614-8484

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe present study aims to evaluate whether differences in accuracy of the implant positions exist for static computer-aided implant placement based on the manufacturing process of surgical guides and the inclusion or not of metal sleeves.

methodsSeventy-two implants (6 per model) were placed in 12 models simulating a partially edentulous maxilla using 12 dentally supported surgical guides anchored with 2 anchor pins. The surgical guides were divided into three groups: additive manufactured with a metal sleeve (Group PS), additive manufactured without a metal sleeve (Group PNS), and subtractive manufactured without a metal sleeve (Group MNS). The internal drilling diameter was standardized for all groups (4.85 mm). Deviations between the planned virtual implant positions and the scanned postoperative models were assessed in three parameters: 3D deviations at the crest, 3D deviations at the apex, and angular deviations in the implant insertion axis. The Shapiro-Wilk test was applied to analyze the normality of the sample distribution. Kruskal-Wallis and Mann-Whitney tests were used to analyze the deviations among the groups (α = 0.05).

resultsStatistical differences were reported among the groups in the parameters: 3D deviations at the crest, 3D deviations at the apex, and angular deviations in the implant insertion axis (p < 0.05). At the crest, the smallest 3D deviation was recorded in the MNS group (0.498 ± 0.337 mm) followed by the PNS group (0.660 ± 0.572 mm) and the PS group (1.028 ± 0.424 mm) (p < 0.05). At the apex, as well, the lowest deviation was observed in the MNS group (0.810 ± 0.544 mm) followed by the PNS group (0.840 ± 0.620) and the PS group (1.360 ± 0.990 mm) (p < 0.05). Regarding angular deviations, the best results were obtained by the PNS group (1.44° ± 1.57°) with statistically significant differences with both the MNS group (2.90° ± 2.35°) and the PS group (3.88° ± 2.85°) (p < 0.05).

conclusionsThe accuracy of the implant position was affected by the inclusion or absence of metal sleeves and the manufacturing method. Overall, non-sleeved guides deliver better accuracy by reducing crestal and apical deviations, as well as angular errors. Differences between the groups without metal sleeves, 3D printed and milled, were found in the implant angulation, where the 3D printed group obtained more accurate results.

Indexed as

Dental Implantation, EndosseousDental ImplantsPrinting, Three-DimensionalSurgery, Computer-AssistedDental Prosthesis DesignHumansMaxillaMetalsDental ImplantsMetals3D printingdental implantsmetal sleevesmillingsleevelessstatic computer‐aided implant placement

Identifiers

PMID40577487
PMCPMC12204604

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.