ArticlePloS one2025
Illegal drugs sensor: Performance evaluation and identification based on terahertz photonic crystal fiber.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Excessive hormone release, the possibility of sleep disturbances, and a brief and quick improvement in the functioning of many organs, the physiological system, the nerves, etc. are all consequences of the abuse of incentive medications. Illegal narcotics have terrible long-term impacts on human health, including the possibility of death, in addition to their immediate effects. These consequences highlight the need for more obviousness and accuracy in the detection of illicit drugs, as well as for their detection to be done gently, effectively, and consistently. This work introduces an illicit drug sensor based on PCF, with an eye toward these as the primary targets. Three illegal drugs - ketamine, amphetamine, and cocaine - have been simulated for the sensor. Two types of circular air holes in cladding of varying sizes have been developed for a single core PCF. The cladding has three-layer chain and wind turbine-shaped air holes, and a circular air hole in the core region that will be used to field test drug samples, all included to achieve low confinement losses and high sensitivity. A maximum Relative Sensitivity (RS) of 99.92%, 99.12% and 98.83% at ketamine, amphetamine, and cocaine respectively is revealed by the recently established PCF analysis, which was presented out right away. Furthermore, we looked at the Confinement Loss (CL) associated with these illicit drugs, which was around 1.275 × 10-7 dB/m, 2.653 × 10-9 dB/m, and 4.106 × 10-10 dB/m, besides Effective Material Loss (EML) of 0.0042 cm-1, 0.0044 cm-1 and 0.0045 cm-1. Refractive index changes in PCF are usually the cause of action for PCF-based biosensors. These modifications have an impact on how light travels within the fiber. Drug molecules interact with light as a result of changes in the optical properties of the core that occur during light propagation through it.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.