Evidence map›Paper›PMID 40574785›Full record

ArticleBMJ surgery, interventions, & health technologies2025

Novel approach to meniscal vascularity evaluation using indocyanine green fluorescence-guided knee arthroscopy.

Tamiko Kamimura

Abstract read
In one paragraph

Article in BMJ surgery, interventions, & health technologies, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Tamiko KamimuraDepartment of Orthopaedic Surgery, Tokorozawa Chuo Hospital, Tokorozawa, Saitama, Japan.ORCID https://orcid.org/0000-0001-5928-1941

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: This study aimed to use indocyanine green (ICG) fluorescence-guided knee arthroscopy to observe the meniscus and surrounding tissue vascularity and determine correlation with the patients' backgrounds. Currently, no data are available on the clinical application of ICG fluorescence-guided knee arthroscopy in assessing meniscal vascularity. Design: Prospective, case series. Setting: In-hospital settings. Participants: 41 knees of 34 patients were examined. 4 knees of 4 patients were included in a pilot study for technique refinement only, while the remaining 37 knees of 30 patients were included in the study. Main outcome measures: The times from ICG administration to fluorescence onset and fluorescence duration from onset to complete attenuation were recorded. The fluorescence intensity at the anterior, middle, and posterior segments of the meniscus was evaluated on a 4-point scale. The younger and older and smoker and non-smoker groups were compared. Results: The average fluorescence onset time was 32.05 s, whereas the average fluorescence duration was 11 min 14 s. The age groups aged≤45 and ≥46 years showed an onset of 30±24.9 and 33.17±16.2 s and a duration of 12 min 54 s and 10 min 20 s, respectively. The smoking and non-smoking groups exhibited an onset of 28.33±14.4 and 33.84±21.5 s and a duration of 10 min 37 s and 11 min 32 s, respectively. All segments of the lateral meniscus showed higher fluorescence intensities than the medial. The posterior segment of the lateral meniscus at ≤45 was markedly more fluorescent and significantly different from ≥46. Conclusions: Fluorescence was observed for approximately 30 s after intravenous ICG injection and lasted approximately 10 min. Fluorescence intensity was brighter in the posterior segment of the lateral meniscus, particularly at ≤45. ICG fluorescence-guided knee arthroscopy may assist in case-specific hemodynamics and real-time surgical evaluation of the meniscus in living humans.

Indexed as

ArthroscopyDevelopment StudyHealth TechnologyTechnology Assessment, Biomedical

Identifiers

PMID40574785
PMCPMC12198815

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.