Evidence map›Paper›PMID 40573514›Full record

ArticleSensors (Basel, Switzerland)2025

Wide-Based Illumination and Detection in Functional Near-Infrared Spectroscopy for Enhanced Seizure Detection in Grey Matter.

Netaniel Rein, Revital Shechter, Evgeny Tsizin, Mordekhay Medvedovsky, Michal Balberg

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Netaniel ReinDepartment of Neurology and Agnes Ginges Center for Human Neurogenetics, Hadassah Medical Organization, Jerusalem 9112001, Israel.
Revital ShechterNeuro Electro Light Center (NELC)-The Joint Research Center of Hadassah Medical Organization and Holon Institute of Technology, Kalman Yaakov Man 2, Jerusalem P.O. Box 12000, Israel.
Evgeny TsizinDepartment of Neurology and Agnes Ginges Center for Human Neurogenetics, Hadassah Medical Organization, Jerusalem 9112001, Israel.
Mordekhay MedvedovskyDepartment of Neurology and Agnes Ginges Center for Human Neurogenetics, Hadassah Medical Organization, Jerusalem 9112001, Israel.
Michal BalbergNeuro Electro Light Center (NELC)-The Joint Research Center of Hadassah Medical Organization and Holon Institute of Technology, Kalman Yaakov Man 2, Jerusalem P.O. Box 12000, Israel.ORCID 0000-0002-3066-1622

Funding

Israel Innovation Authority 82498 and 82499
6 · The paper itself

Abstract

Functional near-infrared spectroscopy (fNIRS) is a non-invasive method for monitoring brain activity by detecting hemodynamic changes. Studies have shown that it can identify ictal and pre-ictal hemodynamic variations, supporting its potential use as a complement to electroencephalography (EEG) in epilepsy monitoring. This study explores an expanded illumination and detection approach utilizing wide-based optodes and increased emitter-detector separation (EDS) to enhance fNIRS sensitivity to cortical hemodynamic changes while minimizing scalp contamination. A Monte Carlo simulation was designed to assess signal amplitude and sensitivity of fNIRS with varying emitter and detector diameters (1-15 mm) and EDS (30-50 mm). Signal strength, grey matter to scalp path ratio (GSPR), and percentage signal change per absorption coefficients (AC) variation were analyzed. Sensitivity to changes in AC of superficial and deep grey matter (SGM, DGM) and scalp was assessed. Increasing emitter and detector diameters substantially increased total detected photon packet weights, enabling practical use at larger EDS. Sensitivity to SGM AC changes tripled at 50 mm EDS, while GSPR increased by 80%, indicating reduced signal contamination from the scalp. Sensitivity to deep cortical hemodynamic changes also improved. Therefore, wide-based fNIRS optodes with increased EDS can enhance seizure-related hemodynamic detection, potentially improving epilepsy diagnostics.

Indexed as

Gray MatterSeizuresElectroencephalographyHemodynamicsHumansMonte Carlo MethodSpectroscopy, Near-InfraredEEGfunctional Near Infrared Spectroscopy (fNIRS)grey matterseizure detection

Identifiers

PMID40573514
PMCPMC12196729

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.