ArticleSensors (Basel, Switzerland)2025
Robust Estimation of Unsteady Beat-to-Beat Systolic Blood Pressure Trends Using Photoplethysmography Contextual Cycles.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Hypertension and blood pressure variability (BPV) are major risk factors for cardiovascular disease (CVD). Single-channel photoplethysmography (PPG) has emerged as a promising daily blood pressure (BP) monitoring tool. However, estimating BP trends presents challenges due to complex temporal dependencies and continuous fluctuations. Traditional methods often address BP prediction as isolated tasks and focus solely on temporal dependencies within a limited time window, which may fall short of capturing the intricate BP fluctuation patterns implied in varying time spans, particularly amidst constant BP variations. To address this, we propose a novel deep learning model featuring a two-stage architecture and a new input structure called contextual cycles. This model estimates beat-to-beat systolic blood pressure (SBP) trends as a sequence prediction task, transforming the output from a single SBP value into a sequence. In the first stage, parallel ResU Blocks are utilized to extract fine-grained features from each cycle. The generated feature vectors are then processed by Transformer layers with relative position encoding (RPE) to capture inter-cycle interactions and temporal dependencies in the second stage. Our proposed model demonstrates robust performance in beat-to-beat SBP trend estimation, achieving a mean absolute error (MAE) of 3.186 mmHg, a Pearson correlation coefficient applied to sequences (Rseq) of 0.743, and a variability error (VE) of 1.199 mmHg. It excels in steady and abrupt substantial fluctuation states, outperforming baseline models. The results reveal that our method meets the requirements of the AAMI standard and achieves grade A according to the BHS standard. Overall, our proposed method shows significant potential for reliable daily health monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.