Evidence map›Paper›PMID 40573490›Full record

ArticleSensors (Basel, Switzerland)2025

Feasibility Study of Using Alternating Current Excitation to Obtain Electrodermal Activity with a Wearable System.

Juan David Romero-Ante, Juan Sebastián Montenegro-Bravo, José María Vicente-Samper, Vicente Manuel Esteve-Sala, Miguel Ángel de la Casa-Lillo, José María Sabater-Navarro

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Juan David Romero-AnteInstitute of Bioengineering, Miguel Hernández University of Elche, 03202 Elche, Spain.ORCID 0000-0002-0893-4647
Juan Sebastián Montenegro-BravoInstitute of Bioengineering, Miguel Hernández University of Elche, 03202 Elche, Spain.ORCID 0009-0005-5989-7750
José María Vicente-SamperDepartment of Civil Engineering, University of Alicante, 03690 San Vicente del Raspeig, Spain.ORCID 0000-0001-7902-1979
Vicente Manuel Esteve-SalaDepartment of Software and Computer Systems, University of Alicante, 03690 San Vicente del Raspeig, Spain.ORCID 0000-0003-4999-4619
Miguel Ángel de la Casa-LilloInstitute of Bioengineering, Miguel Hernández University of Elche, 03202 Elche, Spain.ORCID 0000-0002-7017-2225
José María Sabater-NavarroInstitute of Bioengineering, Miguel Hernández University of Elche, 03202 Elche, Spain.ORCID 0000-0002-3890-6225

Funding

Conselleria d'innovació, Universitats - Generalitat Valenciana CIPROM/2022/16Instituto Valenciano de Competitividad e Innovación INNVA1/2024/59
6 · The paper itself

Abstract

This study investigates the feasibility of using a wearable system with full-wave alternating current (AC) excitation to measure electrodermal activity (EDA). Typically measured using direct current (DC) excitation, EDA is often affected by signal drift due to electrode-skin polarisation. To address this, a portable device was developed that applies fixed-amplitude, full-wave AC signals and records EDA under controlled conditions. The electrical behaviour of the skin was also simulated using a multilayer model to analyse current propagation at different frequencies. The experimental procedure was conducted with ten healthy participants under controlled conditions. Two stages were carried out: the first compared the similarity of the skin conductance level (SCL) between DC and half-wave alternating current (AC) signals; the second analysed signal stability and skin response at full-wave AC excitation. Compared to DC, full-wave AC excitation demonstrated reduced signal drift, greater temporal stability, and enhanced measurement of the skin's capacitive response. These findings support the adoption of AC excitation for EDA measurement, especially in ambulatory and real-time biomechanical applications where signal reliability and stability are essential.

Indexed as

Galvanic Skin ResponseWearable Electronic DevicesAdultElectric ConductivityElectrodesFeasibility StudiesFemaleHumansMaleYoung Adultalternating current (AC)biomechanical systemsconductancedirect current (DC)electrodermal activity (EDA)skin conductance level (SCL)susceptancewearable systems

Identifiers

PMID40573490
PMCPMC12197030

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.