Evidence map›Paper›PMID 40573032›Full record

ArticleMaterials (Basel, Switzerland)2025

Application of Bioinspired Structural Ceramics with High-Temperature Electrical Insulation and High Adhesion in K-Type Coaxial Thermocouples.

Zhenyin Hai, Yue Chen, Zhixuan Su, Yemin Wang, Shigui Gong, Yihang Zhang, Shanmin Gao, Chengfei Zhang, Zhangquan Wang, Hongwei Ji and 2 more

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Zhenyin HaiSchool of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
Yue ChenSchool of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
Zhixuan SuSchool of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
Yemin WangSchool of Aerospace Engineering, Xiamen University, Xiamen 361005, China.ORCID 0009-0009-6242-7361
Shigui GongSchool of Optoelectronics and Communications Engineering, Xiamen University of Technology, Xiamen 361005, China.
Yihang ZhangSchool of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
Shanmin GaoSchool of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
Chengfei ZhangInner Mongolia Aerospace Power Machinery Testing Institute, Hohhot 010076, China.
Zhangquan WangInner Mongolia Aerospace Power Machinery Testing Institute, Hohhot 010076, China.
Hongwei JiInner Mongolia Aerospace Power Machinery Testing Institute, Hohhot 010076, China.
Chenyang XueSchool of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
Zhichun LiuSchool of Aerospace Engineering, Xiamen University, Xiamen 361005, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Surface erosion of the coaxial thermocouple probe initiates continuous bridging of thermoelectric materials on the insulation layer surface, forming new temperature measurement junctions. This inherent ability to measure continuous self-erosion ensures the operational reliability of the coaxial thermocouples in high-temperature ablative environments. However, the fabrication of a high-temperature electrical insulation layer and a high-adhesion insulating layer in the coaxial thermocouples remains a challenge. Inspired by calcium carbonate/oxalate crystals in jujube leaves that strengthen the leaves, a bioinspired structural ceramic (BSC) mimicking these needle-like crystals is designed. This BSC demonstrates excellent high-temperature insulation (with insulation impedance of 2.55 kΩ at 1210 °C) and adhesion strength (35.3 Newtons). The BSC is successfully used as the insulating layer in a K-type coaxial thermocouple. The generation rules for surface junctions are systematically studied, revealing that stable and reliable measurement junctions can be created when the sandpaper grit does not exceed 600#. Static test results show that the K-type coaxial thermocouple ranges from 200 °C to 1200 °C with an accuracy of 1.1%, a drift rate better than 0.0137%/h, and hysteresis better than 0.81%. Dynamic test results show that the response time is 1.08 ms. The K-type coaxial thermocouple can withstand a high-temperature flame impact for 300 s at 1200 °C, as well as over forty cycles of high-power laser thermal shock, while maintaining good response characteristics. Therefore, the K-type coaxial thermocouple designed in this study provides an ideal solution for long-term temperature monitoring of the thermal components of aerospace engines under extremely high-temperature, high-speed, and strong thermal shock conditions.

Indexed as

bioinspiredcoaxial thermocoupledip-coatinghigh-temperature insulationsilicate

Identifiers

PMID40573032
PMCPMC12195117

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.