Evidence map›Paper›PMID 40572825›Full record

ArticleMaterials (Basel, Switzerland)2025

A Finite Element Analysis of a New Dental Implant Design: The Influence of the Diameter, Length, and Material of an Implant on Its Biomechanical Behavior.

Pedro González-Mederos, Jennifer Rodríguez-Guerra, Jesús E González, Alberto Picardo, Yadir Torres

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Pedro González-MederosDepartamento de Biomateriales Cerámicos y Metálicos, Centro de Biomateriales, Universidad de La Habana, Ave. Universidad s/n Entre G y Ronda, Vedado, La Habana 10400, Cuba.
Jennifer Rodríguez-GuerraDepartamento de Biomateriales Cerámicos y Metálicos, Centro de Biomateriales, Universidad de La Habana, Ave. Universidad s/n Entre G y Ronda, Vedado, La Habana 10400, Cuba.
Jesús E GonzálezDepartamento de Biomateriales Cerámicos y Metálicos, Centro de Biomateriales, Universidad de La Habana, Ave. Universidad s/n Entre G y Ronda, Vedado, La Habana 10400, Cuba.
Alberto PicardoDepartamento de Ingeniería del Diseño, Escuela Politécnica Superior de Sevilla, Universidad de Sevilla, Calle Virgen de África, 7, 41011 Sevilla, Spain.ORCID 0000-0002-1456-5198
Yadir TorresIngeniería y Ciencia de los Materiales y del Transporte, Escuela Politécnica Superior de Sevilla, Universidad de Sevilla, Calle Virgen de África, 7, 41011 Sevilla, Spain.ORCID 0000-0001-9042-9641

Funding

Cuban National Science and Technology program: Bio-technology, Pharmaceutical Industry, and Medical Technologies PN385LH007-035: 9827MICIU/AEI/10.13039/501100011033 and ERDF/EU PID2022-137911OB-I00Ministry of Science and Innovation of Spain PDC2022-133369-I00
6 · The paper itself

Abstract

It is widely recognized that excessive stress and/or strain can lead to peri-implant bone atrophy; therefore, the clinical success of dental implants is intrinsically related to their biomechanical behavior. This study evaluates the influence of the diameter, length, and material [Ti6Al4V (α+β Ti) and Ti35Nb7Zr5Ta (β-Ti)] of a novel cylindrical dental implant on stress and strain levels within maxillary bone of type II quality. The implant design aims to ensure an appropriate distribution of stresses and strains within the peri-implant bone structures (cortical and trabecular bones) while also facilitating surgical machining by requiring a simple, linear, and less expensive bone incision. This approach minimizes the risk of thermal necrosis, a common complication in osteotomies for conical implants that can lead to peri-implant bone loss. Using finite element analysis, stress and strain patterns were evaluated in the maxillary second premolar region under static delayed loading. The results reveal that the cortical bone strains remained below the critical threshold (0.003) to prevent resorption. In the trabecular bone, only larger diameter/length configurations satisfied the previous strain criterion. In all simulations, trabecular bone stress remained below 3 MPa, whereas cortical bone stress peaked at 78 MPa. Notably, the implant model with the largest diameter/length minimized stress and strain concentrations in type II bone when compared to smaller designs, thereby demonstrating its biomechanical advantage.

Indexed as

biomechanical behaviordental implantfinite element analysisimplant dimensionsstress shielding Phenomenonβ-Ti alloy

Identifiers

PMID40572825
PMCPMC12194625

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.