ArticleMolecules (Basel, Switzerland)2025
An Activated Glassy Carbon Electrode for Rapid, Simple, and Sensitive Voltammetric Analysis of Diclofenac in Tablets.
Article in Molecules (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper proposes an environmentally friendly sensor for determining trace amounts of diclofenac (DCF)-an activated glassy carbon electrode (aGCE). Such a sensor was achieved by simple surface activation of a glassy carbon electrode to perform five cyclic voltammetric scans from -1.5 to 2.5 V at a scan rate (υ) of 100 mV/s in 0.1 M NaOH. This type of activation results in the formation of surface functional groups, which provide several advantages such as the creation of new active sites, the improvement of electron transfer dynamics, and sensor electrocatalytic activity. The electrode prepared in this way was used to develop a new differential pulse adsorptive stripping voltammetric procedure (DPAdSV) for rapid, simple, and sensitive DCF analysis. Thanks to this procedure, the following calibration curve range was obtained: 1-100 nM with low detection and quantification limits of 0.25 and 0.83 nM, respectively. To show the practical application of the method, DCF was successfully determined in commercially available pharmaceutical preparations with the standard addition method.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.