ArticleMicromachines2025
Study on the Driving Performance and Influencing Factors of Multi-Electrothermal Co-Actuation Devices Considering Application Environments.
Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Recent Advances in MEMS Actuators for Microfluidic Applications: Emerging Designs, Multiphysics Modeling, and Performance Optimization.Micromachines · 2026Review
- Design and Evaluation Method of a High-Overload Test Device Based on AD-TRIZ.Sensors (Basel, Switzerland) · 2025Article
- Experimental and numerical investigations of microthermal actuator employing the amplification theory for achieving competitive performance.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Electrothermal actuators, with their simple structure, small size, strong anti-interference ability, and easy integration, have emerged as a promising solution for micro-drive technology. However, deploying them in extreme environments, such as the fuze systems-which demand exceptional reliability under high mechanical overloads. In this study, a device based on multi-electrothermal co-actuation is designed for the fuze system of loitering munition. The overall structure and work principle of the multi-electrothermal co-actuation device is discussed. Considering application environments, the effect factors of V-beam numbers, air gap, type of contact surface, external load force, periodic voltage and gas damping on the output performance of the multi-electrothermal co-actuation device are systematically addressed via simulation and experimental method. Furthermore, the high overload resistance performance of the co-actuation device applied in loitering munition is studied. The results show that the proposed multi-electrothermal co-actuation device could operate stably under a high overload (12,000 g/73.79 μs) environment, fully meeting the demanding requirements of fuze system for loitering munition. In addition, this study identifies laser processing-induced thermal gradients and mechanical stresses as critical fabrication challenges. This study provides significant insights into the design and optimization of multi-electrothermal actuation systems for next-generation fuze applications, establishing a valuable framework for future development in this field.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.