Evidence map›Paper›PMID 40571926›Full record

Observational studyBMC pediatrics2025

Point of care ultrasound assessment of the optic nerve sheath diameter in critically ill children.

Ahmed A El-Nawawy, Ahmed A El Beheiry, Aya M Abdelaziz, Hadir M Hassouna

Abstract readObservational Study
In one paragraph

Observational study in BMC pediatrics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ahmed A El-NawawyDepartment of Pediatrics, Faculty of Medicine, Alexandria University, Alexandria, Egypt.ORCID 0000-0003-1069-3798
Ahmed A El BeheiryDepartment of Radiolody, Faculty of Medicine, Alexandria University, Alexandria , Egypt.ORCID 0000-0003-3720-2661
Aya M AbdelazizDepartment of Pediatrics, Faculty of Medicine, Alexandria University, Alexandria, Egypt.ORCID 0009-0009-4186-356X
Hadir M HassounaDepartment of Pediatrics, Faculty of Medicine, Alexandria University, Alexandria, Egypt. hadir.hassouna@alexmed.edu.eg.ORCID 0000-0002-2452-9107

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRaised intracranial pressure (ICP) is a typical neurological problem in critically ill children, which is associated with poor clinical outcomes or even death. The purpose of the study was to evaluate the efficacy of optic nerve sheath diameter (ONSD) as a point-of-care testing in the pediatric intensive care units for early diagnosis of raised intracranial pressure and as a follow up tool for treatment response.

methodA prospective observational study was conducted in the pediatric intensive care unit of a tertiary care children's hospital. Consecutive children aged one month to twelve years with Glasgow Coma Scale less than or equal to 8 were included. Brain CT was performed just before or within few hours of admission to identify raised ICP. Two trained examiners in the same work place, who were blinded to the clinical details of the patients, performed the ONSD sonography concurrently. The ONSD was measured in the left and right eyes on admission, after 1 h, after 12 h, and after 24 h.

resultsForty-two patients were categorized into 29 children with raised ICP and 13 children with non-raised ICP. The ONSD was significantly higher in the raised ICP group at all times in both eyes. It showed a significant decrease over time in both groups. A cutoff value of ≥ 4.3 mm was found to be an acceptable discriminator of ICP with Area Under the ROC curve (AUC) = 0.788 (95% CI 0.740- 0.830) (p < 0.0001), sensitivity of 59.91% (95% CI: 53.30-66.27) and specificity of 83.65% (95% CI: 75.12-90.18).

conclusionsIn critically ill children with non-traumatic causes of raised ICP, point of care ultrasound of ONSD shows a good diagnostic test accuracy for early diagnosis of raised ICP as well as follow up tool of treatment response if used serially. In addition, it is very good at correctly identifying individuals who do not have raised ICP to avoid unnecessary interventions.

Indexed as

Intracranial HypertensionOptic NervePoint-of-Care SystemsPoint-of-Care TestingChildChild, PreschoolCritical IllnessEarly DiagnosisFemaleHumansInfantIntensive Care Units, PediatricMaleProspective StudiesROC CurveSensitivity and SpecificityCritically ill childrenIntensive care unitIntracranial pressureNon-invasive monitoringOptic nerve sheath diameterPoint-of- care ultrasound

Identifiers

PMID40571926
PMCPMC12203719

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.