Evidence map›Paper›PMID 40571837›Full record

ArticleIntensive care medicine experimental2025

Digital twins suggest a mechanistic basis for differing responses to increased flow rates during high-flow nasal cannula therapy.

Hossein Shamohammadi, Sina Saffaran, Roberto Tonelli, Valentina Chiavieri, Giacomo Grasselli, Enrico Clini, Tommaso Mauri, Declan G Bates

Abstract read
In one paragraph

Article in Intensive care medicine experimental, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hossein ShamohammadiSchool of Engineering, University of Warwick, Coventry, CV4 7AL, UK.
Sina SaffaranSchool of Engineering, University of Warwick, Coventry, CV4 7AL, UK.
Roberto TonelliRespiratory Diseases Unit, Department of Medical and Surgical Sciences, University Hospital of Modena, University of Modena and Reggio Emilia, Modena, Italy.
Valentina ChiavieriDepartment of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.
Giacomo GrasselliDepartment of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.
Enrico CliniRespiratory Diseases Unit, Department of Medical and Surgical Sciences, University Hospital of Modena, University of Modena and Reggio Emilia, Modena, Italy. enrico.clini@unimore.it.ORCID http://orcid.org/0000-0002-1515-5094
Tommaso MauriDepartment of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.
Declan G BatesSchool of Engineering, University of Warwick, Coventry, CV4 7AL, UK.

Funding

Engineering and Physical Sciences Research Council EP/W000490/1Fisher and Paykel Healthcare R.ESEE.3441Royal Academy of Engineering RF2122-21-258
6 · The paper itself

Abstract

backgroundInconsistent responses to increased flow rates have been observed in patients with acute hypoxemic respiratory failure (AHRF) treated with high-flow nasal cannula (HFNC) therapy, with a significant minority in two recent studies exhibiting increased respiratory effort at higher flow rates. Digital twins of patients receiving HFNC could help understand the physiological basis for differing responses.

methodsPatient data were collated from previous studies in AHRF patients who were continuously monitored with electrical impedance tomography and oesophageal manometry and received HFNC at flow rates of 30, 40 or 45 L/min. Patients, based on their responses to an increase in flow rate to 60 L/min, were categorised into two groups: five responders with reduced oesophageal pressure swings ΔP

resultsThe digital twins accurately replicated patient-specific responses at all flow rates. Responder digital twins showed a mean 20 mL/cmH

conclusionsFailure to reduce spontaneous respiratory efforts in response to increased HFNC flow rates could be due to a deterioration in lung mechanics, with an attendant risk of P-SILI.

Indexed as

Acute hypoxemic respiratory failureDigital twinsHigh flow nasal cannulaNon-invasive respiratory support

Identifiers

PMID40571837
PMCPMC12202274

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.