Evidence map›Paper›PMID 40569316›Full record

ArticleInternational journal of computer assisted radiology and surgery2025

Semi-automatic segmentation of elongated interventional instruments for online calibration of C-arm imaging system.

Negar Chabi, Alfredo Illanes, Oliver Beuing, Daniel Behme, Bernhard Preim, Sylvia Saalfeld

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Negar ChabiFaculty of Computer Science, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany. negar.chabi@isg.cs.ovgu.de.ORCID http://orcid.org/0000-0002-9530-8133
Alfredo IllanesFaculty of Computer Science, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany.
Oliver BeuingDepartment of Radiology, AMEOS Hospital Bernburg, Kustrenaer Str. 98, 06406, Bernburg, Germany.
Daniel BehmeClinic for Neuroradiology, University Hospital of Magdeburg, 39120, Magdeburg, Germany.
Bernhard PreimFaculty of Computer Science, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany.
Sylvia SaalfeldForschungscampus STIMULATE, Magdeburg, Germany.

Funding

partly conducted within the International Graduate School MEMoRIAL at Otto von Guericke University (OVGU) Magdeburg, Germany, which is kindly supported by the European Structural and Investment Funds (ESF) under the program "Sachsen Anhalt WISSENSCHAFT Int ZS/2016/08/80646Part of this work is funded by the Federal Ministry of Education and Research within the Forschungscampus STIMULATE 13GW0473A
6 · The paper itself

Abstract

purposeThe C-arm biplane imaging system, designed for cerebral angiography, detects pathologies like aneurysms using dual rotating detectors for high-precision, real-time vascular imaging. However, accuracy can be affected by source-detector trajectory deviations caused by gravitational artifacts and mechanical instabilities. This study addresses calibration challenges and suggests leveraging interventional devices with radio-opaque markers to optimize C-arm geometry.

methodsWe propose an online calibration method using image-specific features derived from interventional devices like guidewires and catheters (In the remainder of this paper, the term"catheter" will refer to both catheter and guidewire). The process begins with gantry-recorded data, refined through iterative nonlinear optimization. A machine learning approach detects and segments elongated devices by identifying candidates via thresholding on a weighted sum of curvature, derivative, and high-frequency indicators. An ensemble classifier segments these regions, followed by post-processing to remove false positives, integrating vessel maps, manual correction and identification markers. An interpolation step filling gaps along the catheter.

resultsAmong the optimized ensemble classifiers, the one trained on the first frames achieved the best performance, with a specificity of 99.43% and precision of 86.41%. The calibration method was evaluated on three clinical datasets and four phantom angiogram pairs, reducing the mean backprojection error from 4.11 ± 2.61 to 0.15 ± 0.01 mm. Additionally, 3D accuracy analysis showed an average root mean square error of 3.47% relative to the true marker distance.

conclusionsThis study explores using interventional tools with radio-opaque markers for C-arm self-calibration. The proposed method significantly reduces 2D backprojection error and 3D RMSE, enabling accurate 3D vascular reconstruction.

Indexed as

Cerebral AngiographyIntracranial AneurysmCalibrationHumansMachine LearningBiplane X-ray imaging systemC-armCatheterDigital subtraction angiographyMachine learningOnline-calibrationPerspective projectionSegmentation

Identifiers

PMID40569316
PMCPMC12476443

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.