[Development of a balloon sensor device for force-electrical coupling measurement of esophagus].

Peng Ran, Ying Zhong, Yingbing Lai, Lei Liu, Yanhang Zhu, Huantao Zhu

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Peng RanSchool of Life Health Information Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, P. R. China.
Ying ZhongSchool of Life Health Information Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, P. R. China.
Yingbing LaiSchool of Life Health Information Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, P. R. China.
Lei LiuSchool of Life Health Information Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, P. R. China.
Yanhang ZhuSchool of Life Health Information Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, P. R. China.
Huantao ZhuSchool of Life Health Information Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To address the challenges of capturing micro-strains in detecting esophageal motility disorders and the limitations of existing high-resolution manometry and functional intraluminal imaging probes in directly measuring esophageal tissue electrical impedance, this study proposes a novel flexible balloon sensor structure that integrates a piezoelectric film assembly with a distributed impedance electrode array. Using the electrical analysis module in the finite element analysis (FEA) software, simulations of the forward problem for esophageal impedance detection were conducted to optimize the excitation source parameters, and a physical prototype was fabricated. Under a relative excitation mode with a voltage sensitivity of 2.059%, the voltage output characteristics of the impedance electrode array were analyzed during linear changes in the balloon filling volume. Based on the performance variation of the piezoelectric film assembly, 80% was selected as the optimal filling volume. Force-electric coupling tests were conducted on the balloon sensor using a pressure testing platform, revealing that both the piezoelectric film assembly inside the balloon and the impedance electrodes outside the balloon exhibited significant load differentiation characteristics as the force application point shifted. In summary, this balloon sensor facilitates the localization of force application while simultaneously analyzing esophageal tissue properties, offering a novel diagnostic approach and objective tool for esophageal disease detection.

Indexed as

Esophageal Motility DisordersEsophagusManometryElectric ImpedanceElectrodesEquipment DesignFinite Element AnalysisHumansElectrical impedance measurementFlexible balloon sensorForce-electric coupling measurementPolyvinylidene fluoride