Evidence map›Paper›PMID 40566701›Full record

ArticleProceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine2025

A novel approach to flow visualization through mechanical heart valves.

Dylan Goode, Ruby Dhaliwal, Jaymes Schmidt, Kibret Mequanint, Hadi Mohammadi

Abstract read
In one paragraph

Article in Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Bioinspired functional materials for biomedical applications.Frontiers in bioengineering and biotechnology · 2026
    Review
  2. Structural validation of novel bileaflet mechanical heart valve hinge mechanism.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dylan GoodeFaculty of Applied Science, School of Engineering, The Heart Valve Performance Laboratory, University of British Columbia, Kelowna, BC, Canada.
Ruby DhaliwalFaculty of Applied Science, School of Engineering, The Heart Valve Performance Laboratory, University of British Columbia, Kelowna, BC, Canada.
Jaymes SchmidtFaculty of Applied Science, School of Engineering, The Heart Valve Performance Laboratory, University of British Columbia, Kelowna, BC, Canada.
Kibret MequanintDepartment of Chemical and Biochemical Engineering, The Western University, London, ON, Canada.
Hadi MohammadiFaculty of Applied Science, School of Engineering, The Heart Valve Performance Laboratory, University of British Columbia, Kelowna, BC, Canada.ORCID 0000-0003-2089-9167

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mechanical heart valves (MHVs) are indispensable in managing valvular disease, yet they often lack the hemodynamic efficiency of native valves and require lifelong anticoagulation therapy to mitigate thrombus formation. This study introduces a novel bileaflet mechanical heart valve (BMHV), the iValve, designed to address these challenges by more closely emulating native valve performance. Central to this research is the development of a custom-built steady-state flow simulator, which provides a cost-effective and innovative approach to visualizing flow dynamics through MHVs. Unlike traditional methods, this simulator allows for detailed observation of flow patterns, focusing on critical regions such as the central flow and hinge areas.Using the novel flow simulator, the flow through the iValve was compared to that of conventional BMHVs, including the SJM/Abbott Regent and On-X valves. The iValve exhibited significantly reduced flow disturbances and vortex formation in the central flow region and effective hinge washing during the forward flow phase. These preliminary findings suggest that the iValve design minimizes energy loss and shear stress on blood elements, potentially reducing or eliminating the need for anticoagulation therapy. The steady-state flow simulator proved invaluable in these assessments, offering precise, qualitative insights into flow behavior that would be challenging to achieve with other methods. Future work, including pulsatile flow simulations and in vivo testing, will further explore the iValve's clinical potential and validate these promising results.

Indexed as

Heart Valve ProsthesisHydrodynamicsMechanical PhenomenaHemodynamicsHumansModels, CardiovascularProsthesis Designaortic valvescardiovascular engineeringflow visualizationheart simulatorsHeart valvemedical devicesprosthetic heart valvessimulation

Identifiers

PMID40566701
PMCPMC12209540

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.