Evidence map›Paper›PMID 40564488›Full record

ArticleBioengineering (Basel, Switzerland)2025

A Miniaturized Implantable Telemetry Biosensor for the Long-Term Dual-Modality Monitoring of Core Temperature and Locomotor Activity.

Wendi Shi, Hao Huang, Xueting Sun, Qihui Jia, Yu Zhou, Maohua Zhu, Mingqiang Tian, Zhuofan Li, Zepeng Zhang, Tongfei A Wang and 1 more

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Wendi ShiBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.ORCID 0009-0004-6429-8050
Hao HuangBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.
Xueting SunBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.
Qihui JiaBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.
Yu ZhouBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.
Maohua ZhuBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.
Mingqiang TianBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.
Zhuofan LiBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.
Zepeng ZhangNeuCyber NeuroTech (Beijing) Co., Ltd., Beijing 102206, China.
Tongfei A WangBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.
Lei ZhangBeijing Institute for Brain Research, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 102206, China.ORCID 0009-0006-6431-5118

Funding

National Natural Science Foundation of China 32271229
6 · The paper itself

Abstract

Implantable telemetry biosensors have become powerful tools for continuous physiological monitoring with minimal animal perturbation. However, commercially available implants are relatively oversized for small animals such as mice and have limited transmission range, leading to concerns about animal welfare, experiment scenarios, and the reliability of the data. In this study, we designed a telemetry system that tracks the animals' body temperature and locomotor activity in real time. The implant integrates a temperature sensor with a 3-axis accelerometer and is capable of wirelessly transmitting data over a 40 m mesh network. The implant's temperature performance was evaluated in bench tests, showing a response rate of 0.2 °C/s, drift ≤ 0.03 °C within 31 days, and a standard deviation of 0.035 °C across three identically designed implants. Meanwhile, the in vivo implant's locomotion recordings showed strong agreement with computer vision analysis with a correlation coefficient of r = 0.95 (

Indexed as

implantable biosensorsphysiological monitoringtelemetry system

Identifiers

PMID40564488
PMCPMC12189742

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.