Evidence map›Paper›PMID 40564440›Full record

ArticleBioengineering (Basel, Switzerland)2025

Enhanced Aerosol Containment Performance of a Negative Pressure Hood with an Aerodynamic Cap Design: Multi-Method Validation Using CFD, PAO Particles, and Microbial Testing.

Seungcheol Ko, Kisub Sung, Min Jae Oh, Yoonjic Kim, Min Ji Kim, Jung Woo Lee, Yoo Seok Park, Yong Hyun Kim, Ju Young Hong, Joon Sang Lee

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Seungcheol KoSchool of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea.ORCID 0000-0002-0483-0277
Kisub SungSS-ENG Co., Ltd., Bucheon 14449, Republic of Korea.
Min Jae OhAI & Energy Research Center, Korea Photonics Technology Institute, Gwangju 61007, Republic of Korea.
Yoonjic KimDepartment of Emergency Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.ORCID 0000-0002-8084-8874
Min Ji KimEmergency Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
Jung Woo LeeSS-ENG Co., Ltd., Bucheon 14449, Republic of Korea.
Yoo Seok ParkEmergency Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.ORCID 0000-0003-1543-4664
Yong Hyun KimAI & Energy Research Center, Korea Photonics Technology Institute, Gwangju 61007, Republic of Korea.
Ju Young HongEmergency Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.ORCID 0000-0003-3416-3054
Joon Sang LeeSchool of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea.

Funding

Ministry of Health and Welfare RS-2022-KH124483 (HG22C0001),Yonsei university 6-2025-0032
6 · The paper itself

Abstract

Healthcare providers performing aerosol-generating procedures (AGPs) face significant infection risks, emphasizing the critical need for effective aerosol containment systems. In this study, we developed and validated a negative pressure chamber enhanced with an innovative aerodynamic cap structure designed to optimize aerosol containment. Initially, computational fluid dynamics (CFD) simulations were performed to evaluate multiple structural improvement ideas, including air curtains, bidirectional suction, and aerodynamic cap structures. Among these, the aerodynamic cap was selected due to its superior predicted containment performance, practical feasibility, and cost-effectiveness. The CFD analyses employed realistic transient boundary conditions, precise turbulence modeling using the shear stress transport (SST) k-ω model, and detailed droplet evaporation dynamics under realistic humidity conditions. A full-scale prototype incorporating the selected aerodynamic cap was fabricated and evaluated using physical polyalphaolefin (PAO) particle leakage tests and biological aerosol validation with aerosolized

Indexed as

aerosol transmissioncomputational fluid dynamicsintubationrespiratory infection

Identifiers

PMID40564440
PMCPMC12189663

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.