Evidence map›Paper›PMID 40563061›Full record

ArticleCardiovascular engineering and technology2025

Hybrid Biophysics Co-Simulation of a Percutaneous Catheter VAD within a Contractile Left Heart.

Greg W Burgreen, James F Antaki

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular engineering and technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Greg W BurgreenCenter for Advanced Vehicular Systems (CAVS), Mississippi State University, Starkville, MS, 39759, USA.ORCID 0000-0003-3953-6307
James F AntakiMeinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA. antaki@cornell.edu.ORCID 0000-0002-5430-7353

Funding

Multiscale Model of Thrombosis in Artificial CirculationR01HL089456 · NHLBI · CORNELL UNIVERSITY · PI ANTAKI, JAMES F., BUTCHER, JONATHAN TALBOT · 2009 to 2024
$8.5M
Identifying and Facilitating Ventricular Recovery on Mechanical SupportR01HL086918 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI GORCSAN, JOHN · 2007 to 2011
$3.8M
NHLBI NIH HHS R01 HL086918NHLBI NIH HHS R01 HL089456
6 · The paper itself

Abstract

purposeVentricular assist devices (VADs) are most often computationally evaluated as isolated devices subjected to idealized steady-state blood flow conditions. In clinical practice, these devices are connected to, or within, diseased pulsatile ventricles of the heart, which can dramatically affect the hemodynamics, hence hemocompatibility-related adverse events such as hemolysis, bleeding, and thrombosis. Therefore, improved simulations are needed to more realistically represent the coupling of devices to the assisted ventricle.

methodsTo address this need, we present a hybrid biophysics co-simulation strategy to evaluate the blood flow dynamics of a percutaneous catheter VAD in-situ within a pulsatile ventricle coupled to the circulation. Our hybrid strategy utilizes a computationally inexpensive lumped parameter network (LPN) to compute cardiac dynamics and provide one-way coupled physiologically-realistic boundary conditions to a high-fidelity computational fluid dynamics (CFD) model to simulate detailed hemodynamics of the VAD and the VAD-assisted left heart.

resultsNumerical simulation of a high-speed rotodynamic catheter pump configured as a left ventricular assist device (LVAD) generated a realistic reproduction of the unsteady blood velocity field over one complete cardiac cycle. The biophysics co-simulation strategy resulted in approximately one order of magnitude speed-up compared to a bidirectionally coupled CFD co-simulation. The simulated flow fields revealed persistent swirling blood flow within the ventricle, unsteady flow discharged to aorta by the pump, and significant variations of surface washing around the pump housing during the cardiac cycle.

conclusionsThis study represents a stepping stone toward physiologically and anatomically realistic evaluation of mechanical circulatory support devices that directly complements and reduces extensive in-vivo studies to mitigates risk of adverse events in the clinical setting.

Indexed as

Cardiac CathetersComputer SimulationHeart-Assist DevicesHemodynamicsModels, CardiovascularMyocardial ContractionVentricular Function, LeftBlood Flow VelocityHumansNumerical Analysis, Computer-AssistedProsthesis DesignPulsatile FlowCatheter pumpComputational fluid dynamicsPulsatile left heartTemporary LVADTemporary mechanical circulatory support

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.