Evidence map›Paper›PMID 40562692›Full record

ArticleBMJ paediatrics open2025

Accuracy and utility of newborn foot length screening tools to identify small babies by mothers in Sidama Region, Ethiopia.

Fitsum Weldegebriel Belay, Fanuel Belayneh Bekele, Rekiku Fikre, Akalewold Alemayehu, Hannah Richards, Andrew Clarke, Sarah Williams, Yohannes Chanyalew Kassa

Abstract read
In one paragraph

Article in BMJ paediatrics open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Fitsum Weldegebriel BelayDepartment of Pediatrics and Child Health, Hawassa University College of Medicine and Health Sciences, Hawassa, Ethiopia fitsedememmj@gmail.com.ORCID http://orcid.org/0000-0002-9671-7422
Fanuel Belayneh BekelePublic Health, Hawassa University, Hawassa, Ethiopia.ORCID http://orcid.org/0000-0001-7021-0773
Rekiku FikreMidwifery, Hawassa University, Hawassa, Ethiopia.ORCID http://orcid.org/0000-0003-1324-1631
Akalewold AlemayehuHawassa University College of Medicine and Health Sciences, Hawassa, Ethiopia.ORCID http://orcid.org/0000-0002-6448-6092
Hannah RichardsGlobal Programmes, Save the Children Fund, London, UK.
Andrew ClarkeLancaster University, Lancaster, UK.ORCID http://orcid.org/0000-0003-3127-5309
Sarah WilliamsSave the Children UK, London, UK.
Yohannes Chanyalew KassaHealth and Nutrition, Save the Children Ethiopia Country Office, Addis Ababa, Ethiopia.ORCID http://orcid.org/0009-0009-9644-0839

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSimple, low-cost anthropometric screening tools like foot length (FL) can be used to screen for small babies (low birth weight (LBW) or preterm) delivered at home or in facilities where functional weighing scales are unavailable. This study aimed to evaluate the accuracy and utility of newborn FL screening tools to help identify small babies by mothers.

methodsA mixed-method study was conducted at selected health facilities from 15 May to 6 July 2024. The consecutive sample included 396 mother-newborn dyads. Mothers screened newborns using laminated cards and plastic tools with colour codes (green/red) based on a 73 mm FL cut-off. In-depth interviews were also conducted with purposively selected participating mothers. The screening tools' diagnostic accuracy was evaluated by receiver operating characteristic curve analyses.

resultsThe mean maternal age was 26.9 years. There were 61 (15.4%) LBW and 48 (12.3%) preterm babies. Using the laminated card, mothers classified 39.4% of newborns as having a short foot, while 33.1% were classified as such using the plastic tool. The plastic tool showed LBW identification accuracy of 0.82 area under receiver operating characteristic curve (AUC): 0.82 (95% CI 0.77 to 0.87) compared with the laminated card AUC: 0.75 (95% CI 0.69 to 0.81). For preterm identification, both tools performed similarly (AUC: 0.73-0.74). Compared with the laminated card (81.9% sensitivity and 68.4% specificity), the plastic tool (86.9% sensitivity and 76.7% specificity) would miss fewer LBW babies and reduce unnecessary referrals. The qualitative findings also suggested that a smooth surface, footprint picture, colour codes and heel holder can increase acceptability and utilisation of the FL screening tools.

conclusionFL screening tools made from plastic or card with colour codes can be used by mothers to help identify LBW and preterm babies. Area-specific cut-off points, a smooth surface with a footprint picture and a heel holder, should be considered while designing colour-coded FL screening tools.

Indexed as

AnthropometryFootInfant, Low Birth WeightMothersNeonatal ScreeningAdultEthiopiaFemaleHumansInfant, NewbornInfant, PrematureMaleROC CurveYoung AdultHealth PolicyInfantLow and Middle Income CountriesNeonatology

Identifiers

PMID40562692
PMCPMC12198826

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.