Evidence map›Paper›PMID 40558448›Full record

ArticleBiosensors2025

Polypyrrole Coatings as Possible Solutions for Sensing and Stimulation in Bioelectronic Medicines.

Cristian Sevcencu, Izabella Crăciunescu, Alin-Alexandru Andrei, Maria Suciu, Sergiu Macavei, Lucian Barbu-Tudoran

Abstract read
In one paragraph

Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Cristian SevcencuNational Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), 400293 Cluj-Napoca, Romania.ORCID 0000-0002-1240-3400
Izabella CrăciunescuNational Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), 400293 Cluj-Napoca, Romania.
Alin-Alexandru AndreiNational Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), 400293 Cluj-Napoca, Romania.
Maria SuciuNational Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), 400293 Cluj-Napoca, Romania.
Sergiu MacaveiNational Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), 400293 Cluj-Napoca, Romania.
Lucian Barbu-TudoranNational Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), 400293 Cluj-Napoca, Romania.

Funding

the Romanian Ministry of Education and Research, Program "Nucleu" Not Applicable
6 · The paper itself

Abstract

Bioelectronic medicines record biological signals and provide electrical stimulation for the treatment of diseases. Advanced bioelectronic therapies require the development of electrodes that match the softness of the implanted tissues, as the present metal electrodes do not meet this condition. The objective of the present work was to investigate whether the electroconductive polymer polypyrrole (PPy) could be used for fabricating such electrodes, as PPy is several orders softer than metals. For this purpose, we here investigated if electrodes made using coatings and films of PPy doped with naphthalin-2-sulfonic acid (PPy/N) are capable to record and elicit by stimulation cardiac monophasic action potentials (MAPs) and if PPy/N is also biocompatible. The results of this study showed that the tested PPy/N electrodes are capable of recording MAPs almost identical to the MAPs recorded with platinum electrodes and eliciting stimulation-evoked MAPs almost identical to the spontaneous MAPs. In addition, we show here that the cell cultures that we used for biocompatibility tests grew in a similar manner on PPy/N and platinum substrates. We, therefore, conclude that PPy/N coatings and films have recording and electrical stimulation capabilities that are similar to those of platinum electrodes and that PPy/N substrates are as biocompatible as the platinum substrates.

Indexed as

Biosensing TechniquesPolymersPyrrolesAction PotentialsAnimalsElectric StimulationElectrodesHumansPolymerspolypyrrolePyrrolesaction potentialsbioelectronic medicinepolypyrrolerecordingstimulation

Identifiers

PMID40558448
PMCPMC12190311

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.