The Effect of Three-Dimensional Stabilization Thread Design on Biomechanical Fixation and Osseointegration in Type IV Bone.

Nicholas J Iglesias, Vasudev Vivekanand Nayak, Arthur Castellano, Lukasz Witek, Bruno Martins de Souza, Edmara T P Bergamo, Ricky Almada, Blaire V Slavin, Estevam A Bonfante, Paulo G Coelho

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Nicholas J IglesiasDeWitt Daughtry Family Department of Surgery, University of Miami Miller School of Medicine, Miami, FL 33136, USA.ORCID 0000-0002-5935-997X
Vasudev Vivekanand NayakDepartment of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA.ORCID 0000-0003-2739-0339
Arthur CastellanoMackenzie Evangelical School of Medicine Paraná, Curitiba 80730-000, PR, Brazil.
Lukasz WitekBiomaterials and Regenerative Biology Division, NYU College of Dentistry, New York, NY 10010, USA.ORCID 0000-0003-1458-6527
Bruno Martins de SouzaBiomaterials and Regenerative Biology Division, NYU College of Dentistry, New York, NY 10010, USA.ORCID 0000-0002-1075-0441
Edmara T P BergamoDepartment of Prosthodontics, NYU College of Dentistry, New York, NY 10010, USA.
Ricky AlmadaDepartment of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA.
Blaire V SlavinUniversity of Miami Miller School of Medicine, Miami, FL 33136, USA.
Estevam A BonfanteDepartment of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru 17012-901, SP, Brazil.
Paulo G CoelhoDepartment of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA.

Funding

Field Emission Scanning Electron MicroscopeS10OD026989 · OD · NEW YORK UNIVERSITY · PI BROMAGE, TIMOTHY G. · 2019 to 2019
$581k
BioHorizons® (Birmingham, AL, USA) N/ANIH HHS S10 OD026989
6 · The paper itself

Abstract

Achieving the appropriate primary stability for immediate or early loading in areas with low-density bone, such as the posterior maxilla, is challenging. A three-dimensional (3D) stabilization implant design featuring a tapered body with continuous cutting flutes along the length of the external thread form, with a combination of curved and linear geometric surfaces on the thread's crest, has the capacity to enhance early biomechanical and osseointegration outcomes compared to implants with traditional buttressed thread profiles. Commercially available implants with a buttress thread design (TP), and an experimental implant that incorporated the 3D stabilization trimmed-thread design (TP 3DS) were used in this study. Six osteotomies were surgically created in the ilium of adult sheep (N = 14). Osteotomy sites were randomized to receive either the TP or TP 3DS implant to reduce site bias. Subjects were allowed to heal for either 3 or 12 weeks (N = 7 sheep/time point), after which samples were collected en bloc (including the implants and surrounding bone) and implants were either subjected to bench-top biomechanical testing (e.g., lateral loading), histological/histomorphometric analysis, or nanoindentation testing. Both implant designs yielded high insertion torque (ITV ≥ 30 N⋅cm) and implant stability quotient (ISQ ≥ 70) values, indicative of high primary stability. Qualitative histomorphological analysis revealed that the TP 3DS group exhibited a continuous bone-implant interface along the threaded region, in contrast to the TP group at the early, 3-week, healing time point. Furthermore, TP 3DS's cutting flutes along the entire length of the implant permitted the distribution of autologous bone chips within the healing chambers. Histological evaluation at 12 weeks revealed an increase in woven bone containing a greater presence of lacunae within the healing chambers in both groups, consistent with an intramembranous-like healing pattern and absence of bone dieback. The TP 3DS macrogeometry yielded a ~66% increase in average lateral load during pushout testing at baseline (T = 0 weeks,

Indexed as

implant stability quotientinsertion torque valuelateral loadingnanoindentationosseointegrationprimary stability

Identifiers

PMID40558364
PMCPMC12190597

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.