ArticleACS measurement science au2025
Implications of Extra-column Effects for Targeted or Untargeted Microflow LC-MS.
Article in ACS measurement science au, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Mass spectrometry (MS) has changed our understanding of health, disease, and the environment through untargeted analyses where entire molecular classes are investigated. These techniques generate huge amounts of data which when processed by statistical tools can identify important molecular features or biomarkers. The complexities of these samples are not compatible with direct introduction to the MS system and require a high-resolution separation step, typically low flow liquid chromatography (LC), prior to MS. LC columns that can produce adequate linear velocities at these low flow rates are small in volume making their results susceptible to resolution loss in extra-column volumes. Here, we investigate the implications of the extra-column effects in five LC-MS systems with triple quadrupole and orbitrap mass analyzers. The extra-column volume of these systems in their standard configuration ranged from 26.4 to 78.1 μL which we reduced to 9.57 to 18.7 μL by optimizing the fluidics. The effects of this volume reduction were assessed by studying a hydrolyzed protein sample in a proteomics environment where the intensity of the largest MS peak was improved by 1.8-3.8×. Additionally, the number of molecular features detected in the protein sample improved by up to 7.5×. The relationship between extra-column volumetric variance and flow rate shows that broadening will become much larger for MS detectors at higher flow rates, unlike a traditional small volume UV detector. The methods, applications, and theoretical insights in this work can be used to improve the mass spectrometric results of any LC-MS system.