Evidence map›Paper›PMID 40556874›Full record

ArticleACS measurement science au2025

Understanding Sensitivity in Nanoscale Sensing Devices.

Dominik Duleba, Adria Martínez-Aviñó, Andriy Revenko, Robert P Johnson

Abstract read
In one paragraph

Article in ACS measurement science au, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Dominik DulebaSchool of Chemistry, University College Dublin, Belfield, Dublin 4, Ireland.ORCID https://orcid.org/0000-0002-0618-2162
Adria Martínez-AviñóSchool of Chemistry, University College Dublin, Belfield, Dublin 4, Ireland.
Andriy RevenkoSchool of Chemistry, University College Dublin, Belfield, Dublin 4, Ireland.
Robert P JohnsonSchool of Chemistry, University College Dublin, Belfield, Dublin 4, Ireland.ORCID https://orcid.org/0000-0002-8046-2138

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In nanoscale sensors, understanding and predicting sensor sensitivity is challenging as the physical phenomena that govern the transduction mechanism are often highly nonlinear and highly coupled. The sensitivity of a sensor is related to both the magnitude of the analyte-caused signal change and the random error-caused fluctuation of the sensor's output. The extent to which these can be controlled, by carefully designing either the geometric or operating conditions of the sensor, determines the difference in signal output between the presence and absence of the analyte, as well as the impact of random errors on the distribution of these signal outputs. Herein, we use ion-current-rectifying nanopore sensors as a simplified case study to show how geometric and operating parameters can enable sensitivity optimization. Finite element analysis is used to obtain distributions of the sensor output, and then, Sobol analysis is used to highlight the most important contributions to sensor output errors. Furthermore, the magnitude of the signal change is considered alongside the spread of the output to calculate and optimize the sensor sensitivity. We highlight that the most important parameters contributing to the output variance are geometric. We observed that as the sensor is operated at smaller pore radii and lower electrolyte concentrations, the influence of the cone angle errors increases, the influence of the pore radius errors decreases, and the output becomes broader. We also show that the highest sensitivity is expected for larger pores operated at low electrolyte concentrations, and our simulation results are validated by experimental results. Recommendations to achieve optimum sensitivity are given for a range of nanopore scenarios in which ion-rectifying nanopore sensors may be used. This work aims to provide a framework for the nanoscale community to optimize sensitivity using simulations, as the analysis highlighted herein is viable for any system that can be modeled using continuum physics.

Indexed as

nanopipettenanoporeoptimizationsensitivitysensorSoboluncertainty

Identifiers

PMID40556874
PMCPMC12183584

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.