Evidence map›Paper›PMID 40553185›Full record

ArticleForensic toxicology2026

Quantitative analysis of ethylene glycol in human serum by liquid chromatography-tandem mass spectrometry with p-toluenesulfonyl isocyanate derivatization.

Shin Ogawa, Ryosuke Shiraki, Kengo Wakigawa, Hidehiko Okazaki, Akira Tsujita, Akinaga Gohda, Toshiro Matsui

Abstract read
PubMed Publisher
In one paragraph

Article in Forensic toxicology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shin OgawaDepartment of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School of Kyushu University, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan. s.ogawa.hrk@gmail.com.ORCID 0009-0008-8036-5734
Ryosuke ShirakiForensic Science Laboratory, Fukuoka Prefectural Police Headquarters, 7-7 Higashikoen, Hakata-ku, Fukuoka, 812-8576, Japan.
Kengo WakigawaForensic Science Laboratory, Fukuoka Prefectural Police Headquarters, 7-7 Higashikoen, Hakata-ku, Fukuoka, 812-8576, Japan.
Hidehiko OkazakiForensic Science Laboratory, Fukuoka Prefectural Police Headquarters, 7-7 Higashikoen, Hakata-ku, Fukuoka, 812-8576, Japan.
Akira TsujitaForensic Science Laboratory, Fukuoka Prefectural Police Headquarters, 7-7 Higashikoen, Hakata-ku, Fukuoka, 812-8576, Japan.
Akinaga GohdaForensic Science Laboratory, Fukuoka Prefectural Police Headquarters, 7-7 Higashikoen, Hakata-ku, Fukuoka, 812-8576, Japan.
Toshiro MatsuiDepartment of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School of Kyushu University, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan. tmatsui@agr.kyushu-u.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEthylene glycol (EG) is a typical antifreeze compound and a significant analyte in forensic toxicology. Current EG analytical method for biological samples in forensic toxicology employ liquid chromatography-tandem mass spectrometry (LC-MS/MS), however, they exhibit low sensitivity and reliability. Therefore, in this study, we aimed to establish a highly sensitive, selective, and reliable EG assay system for human serum analysis using a hydroxyl derivatization-aided LC-MS/MS technique.

methodsp-Toluenesulfonyl isocyanate (PTSI) was applied for precolumn derivatization of EG in human serum, to enhance the sensitivity of LC-MS/MS for EG detection.

resultsThe optimal derivatization conditions were 200 µL/mL PTSI in acetonitrile at 25 °C for 10 min. A highly sensitive and reliable LC-MS/MS detection of EG in human serum was achieved, with the calibration curve exhibiting a good linearity (r > 0.999, 10-1000 µg/mL of EG). The proposed PTSI-derivatization-LC-MS/MS method exhibited high reliability (1.4-1.8%) for the intra-day and inter-day repeatability (%RSD), and accuracy (96.7-102.4%), with the limits of detection and quantification in human serum being 0.023 µg/mL (S/N = 3) and 0.077 µg/mL (S/N = 10), respectively.

conclusionsA novel PTSI derivatization-aided LC-MS/MS method was developed, offering a highly sensitive, selective, and reliable analytical tool for EG quantification in human serum for forensic toxicology applications.

Indexed as

Ethylene GlycolChromatography, LiquidForensic ToxicologyHumansReproducibility of ResultsTandem Mass SpectrometryEthylene GlycolDerivatizationEthylene glycolHuman serumLC–MS/MSp-Toluenesulfonyl isocyanate

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked